COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
|
| FURNACE** | COIL |
|
| COOLING |
|
| ||
UNIT MODEL | CFM RANGE |
| RATED | NET MBH | SEER1 |
| ||||
W | MODEL | EER | ||||||||
| CFM |
|
| |||||||
| TOTAL | SENS. | ||||||||
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| |
| 450 | - 750 | 14,17 | FC/MC/PC18 | 600 | 17.5 | 12.9 | 13.00 | 11.00 | |
YCJD18S41S1(H) | 450 - 750 | 14 | HC18 | 600 | 17.5 | 12.9 | 13.00 | 11.00 | ||
| 450 | - 750 | 14,17 | UC18 | 600 | 17.5 | 12.9 | 13.00 | 11.00 | |
| 600 - 1000 | 14 | FC/MC/PC32 | 800 | 24.0 | 16.7 | 13.00 | 11.00 | ||
| 600 - 1000 | 17,21 | FC/MC/PC35 | 800 | 24.0 | 16.7 | 13.00 | 11.00 | ||
| 600 - 1000 | 14,17,21 | FC/MC/PC36 | 800 | 24.0 | 16.7 | 13.00 | 11.00 | ||
| 600 - 1000 | 14 | FC/MC/PC37 | 800 | 24.0 | 16.7 | 13.00 | 11.00 | ||
YCJD24S41S1(H) | 600 - 1000 | 17,21 | FC/MC/PC43 | 800 | 24.0 | 16.7 | 13.00 | 11.00 | ||
| 600 - 1000 | 14 | HC30 | 800 | 24.0 | 16.7 | 13.00 | 11.00 | ||
| 600 - 1000 | 17 | HC36 | 800 | 24.0 | 16.7 | 13.00 | 11.00 | ||
| 600 - 1000 | 21 | HC42 | 800 | 24.0 | 16.7 | 13.00 | 11.00 | ||
| 600 - 1000 | 14,17,21 | UC36 | 800 | 24.0 | 16.7 | 13.00 | 11.00 | ||
| 800 - 1200 | 14 | FC/MC/PC32 | 1000 | 29.0 | 21.0 | 13.00 | 11.00 | ||
| 800 - 1200 | 17,21 | FC/MC/PC35 | 1000 | 29.0 | 21.0 | 13.00 | 11.00 | ||
YCJD30S41S1(H) | 800 - 1200 | 14 | FC/MC/PC37 | 1000 | 29.0 | 21.0 | 13.00 | 11.00 | ||
800 - 1200 | 17,21 | FC/MC/PC43 | 1000 | 29.0 | 21.0 | 13.00 | 11.00 | |||
| ||||||||||
| 800 - 1200 | 17 | HC36 | 1000 | 29.0 | 21.0 | 13.00 | 11.00 | ||
| 800 - 1200 | 21 | HC42 | 1000 | 29.0 | 21.0 | 13.00 | 11.00 | ||
| 1000 | - 1400 | 14 | FC/MC/PC37 | 1200 | 35.0 | 24.8 | 13.00 | 11.00 | |
| 1000 | - 1400 | 17,21 | FC/MC/PC43 | 1200 | 35.0 | 24.8 | 13.00 | 11.00 | |
YCJD36S41S1(H) | 1000 - 1400 | 21,24 | FC/MC/PC48 | 1200 | 35.0 | 24.8 | 13.00 | 11.00 | ||
| 1000 | - 1400 | 21 | HC42 | 1200 | 35.0 | 24.8 | 13.00 | 11.00 | |
| 1000 | - 1400 | 21,24 | UC48 | 1200 | 35.0 | 24.8 | 13.00 | 11.00 | |
| 1200 | - 1600 | 17,21 | FC/MC/PC43 | 1400 | 42.0 | 29.2 | 13.00 | 11.00 | |
YCJD42S41S1(H) | 1200 | - 1600 | 21,24 | FC/MC/PC48 | 1400 | 42.0 | 29.2 | 13.00 | 11.00 | |
1200 | - 1600 | 21 | HC42 | 1400 | 42.0 | 29.2 | 13.00 | 11.00 | ||
| ||||||||||
| 1200 | - 1600 | 21,24 | UC48 | 1400 | 42.0 | 29.2 | 13.00 | 11.00 | |
| 1400 | - 1800 | 21,24 | FC/MC/PC48 | 1600 | 48.0 | 34.4 | 13.00 | 11.00 | |
| 1400 | - 1800 | 21,24 | FC/MC/PC60 | 1600 | 48.0 | 34.4 | 13.00 | 11.00 | |
YCJD48S41S1(H) | 1400 - 1800 | 24 | HC60 | 1600 | 48.0 | 34.4 | 13.00 | 11.00 | ||
| 1400 | - 1800 | 21,24 | UC48 | 1600 | 48.0 | 34.4 | 13.00 | 11.00 | |
| 1400 | - 1800 | 21,24 | UC60 | 1600 | 48.0 | 34.4 | 13.00 | 11.00 | |
| 1600 | - 2000 | 21,24 | FC/MC/PC60 | 1800 | 57.0 | 38.5 | 13.00 | 11.00 | |
YCJD60S41S1 | 1600 | - 2000 | 24 | FC/MC62 | 1800 | 57.0 | 38.5 | 13.00 | 11.00 | |
1600 | - 2000 | 24 | HC60 | 1800 | 57.0 | 38.5 | 13.00 | 11.00 | ||
| ||||||||||
| 1600 | - 2000 | 21,24 | UC60 | 1800 | 57.0 | 38.5 | 13.00 | 11.00 |
1.Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace