York YP9C*C YTG-A-0809, Left Side, Front, Right Side, Optional Return Air, Cutout Either side

Models: YP9C*C

1 4
Download 4 pages 41.97 Kb
Page 2
Image 2
538513- YTG-A-0809

538513- YTG-A-0809

 

 

 

 

 

 

LEFT SIDE

 

FRONT

 

RIGHT SIDE

 

 

Combustion Air Inlet

 

 

Combustion Air Inlet

 

 

 

 

 

 

 

Condensate Drain

 

Gas Pipe

Gas Pipe

Condensate Drain

 

 

(Downflow)

 

Entry

 

 

 

 

 

Entry

(Downflow)

 

 

2” Vent

 

Electrical

Electrical

 

 

 

Connection

 

Entry

2” Vent

 

 

 

Entry

 

 

Outlet

 

 

Connection

 

 

 

Condensate

 

 

 

 

 

 

 

 

 

 

33”

Outlet

 

 

 

 

Drain

 

 

 

 

 

 

 

 

 

 

Condensate

23”

 

 

 

 

 

Drain

 

 

 

 

Thermostat

 

 

 

 

 

 

 

 

 

 

 

Wiring

Thermostat

Optional Return Air

 

 

 

 

 

Wiring

14”

 

 

 

 

Cutout (Either side)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1”

 

28.5”

 

A

 

1.5”

 

 

30.25”

 

 

 

 

 

.56”

 

 

 

 

 

 

 

23.8”

3”

2” Vent

 

 

 

 

 

 

 

 

 

 

 

 

Connection

 

 

 

 

 

 

Outlet

 

 

 

B

Combustion

 

 

 

 

B

 

Air Inlet

 

C

 

 

 

 

 

 

 

 

 

.56”

.56”

 

 

 

24.25”

 

20”

 

 

 

 

 

 

 

 

 

RETURN END

 

 

SUPPLY END

 

 

 

 

 

 

 

 

 

 

Cabinet and Duct Dimensions

Models

Nominal CFM

Cabinet Size

 

Cabinet Dimensions (Inches)

 

 

 

 

 

 

 

 

 

A

 

B

 

C

YP9C060B12MP12C

1200

B

17 1/2

 

16 3/8

 

13 1/4

YP9C080B12MP12C

1200

B

17 1/2

 

16 3/8

 

14 3/4

YP9C080C16MP12C

1600

C

21

 

19 7/8

 

16 1/2

YP9C100C16MP12C

1600

C

21

 

19 7/8

 

18 1/4

YP9C100C20MP12C

2000

C

21

 

19 7/8

 

18 1/4

YP9C120D20MP12C

2000

D

24 1/2

 

23 3/8

 

21 3/4

Ratings & Physical / Electrical Data

 

Input

Output

 

AFUE

Nominal

Total

Air Temp.

Air Temp.

Models

Max/Min

Max/Min

 

Airflow

Unit

Rise Max Input

Rise Min Input

 

 

 

 

 

 

 

 

Amps

 

 

 

MBH

MBH

 

%

CFM

°F

°F

YP9C060B12MP12C

60/21

58/20

 

97.5

1200

7.0

40-70

20-50

YP9C080B12MP12C

80/28

77/27

 

97.5

1200

7.5

40-70

20-50

YP9C080C16MP12C

80/28

78/27

 

97.7

1600

10.0

40-70

20-50

YP9C100C16MP12C

100/35

97/34

 

97.7

1600

10.0

40-70

20-50

YP9C100C20MP12C

100/35

97/34

 

97.7

2000

12.0

45-75

25-55

YP9C120D20MP12C

120/42

116/40

 

98.0

2000

12.0

45-75

25-55

 

Max. Outlet

Blower

 

Blower

Max

Min. wire Size

Approximate

Models

Air Temp

 

Over-Current

(awg) @ 75 ft

Operating Weights

 

 

 

Wheel Size

 

 

 

 

 

Protect

one way

 

 

°F

HP

 

Amps

 

Lbs

YP9C060B12MP12C

170

1/2

 

4.8

11 x 8

15

14

113

YP9C080B12MP12C

175

1/2

 

4.8

11 x 8

15

14

119

YP9C080C16MP12C

175

3/4

 

7.5

11 x 10

15

14

134

YP9C100C16MP112C

175

3/4

 

7.5

11 x 10

15

14

140

YP9C100C20MP12C

180

1

 

14.5

11 x 11

20

12

143

YP9C120D20MP12C

180

1

 

14.5

11 x 11

20

12

152

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.

Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water.

2

Johnson Controls Unitary Products

Page 2
Image 2
York YP9C*C YTG-A-0809, Left Side, Front, Right Side, Optional Return Air, Cutout Either side, Return End, Supply End