Zanussi CH 6029 GR Installation Instructions, Electrical Connections, Electrical Requirements

Models: CH 6029 GR

1 20
Download 20 pages 40.65 Kb
Page 10
Image 10
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

It is dangerous to alter the specifications or attempt to modify this product in any way.

Technical Information

 

 

DIMENSIONS

HEIGHT:

20.00cm

 

WIDTH

52.20cm

 

DEPTH

28.50cm

 

DUCTING OUTLET:

120mm

WEIGHT

GROSS:

4.8kg

 

NET:

5.8kg

ELECTRICAL SUPPLY:

Voltage (50Hz)

220-240 V

POWER CONSUMPTION:

 

175 W

FAN MOTOR:

 

95W

LAMP:

 

80W

SUITABLE FOR INSTALLATION

 

 

ABOVE:

ELECTRIC HOB:

7KW (max)

 

GAS HOB:

10KW (max)

 

SLOT-IN GAS COOKER:

13.5KW (max)

 

SLOT-IN ELECTRIC COOKER:

12.4KW (max)

Note: CE Marking certifies that this appliance complies with the require- ments laid down in EEC directive 89:336. (Electromagnetic compatibility) and subsequent modifications and Low Voltage directive 72/23/E.

ELECTRICAL CONNECTIONS

WARNING: DOUBLE INSULATED-DO NOT EARTH

Electrical Requirements

Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety this should be undertaken by a qualified electrician e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC).

Electrical Connection

Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood.

This appliance is fitted with a 2 core mains cable and must be permanently connected to the electricity supply via a double-pole switch having 3mm minimum contact gap on each pole. A Switched Fuse Connection Unit to BS1363 Part 4, fitted with a 3 Amp fuse, is a recommended mains supply connection accessory to ensure compliance with the Safety Requirements applicable to fixed wiring instructions.

This appliance conforms to BS 800: 1988 and EEC Directive No. 78 308 regarding suppression of radio and television interference.

10

Page 10
Image 10
Zanussi CH 6029 GR Installation Instructions, Electrical Connections, Electrical Requirements, Technical Information, Lamp