Installation

Installation

The oven must be installed according to the instructions supplied.

This oven must be installed by qualified personnel to the relevant British Standards.

Technical Data

 

DIMENSIONS

Height

580 mm.

 

OF RECESS

Width

560-570 mm.

 

 

Depth

550 mm.

 

 

 

 

 

DIMENSIONS

Height

320 mm.

 

OF THE

Width

420 mm.

 

OVEN CAVITY

Depth

390 mm.

 

 

Oven capacity 53.2 litres

 

 

 

 

Heating elements rating

Oven element

2.08 kW

Grill element

1.82 kW

 

 

Oven Light

15 W

 

 

Cooling Fan

25 W

 

 

Convection Fan

30 W

 

 

Total Rating

2.15 kW

 

 

Electrical Connection

The oven is designed to be connected to 240V (50Hz) electricity supply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

 

 

 

 

 

 

 

or E

-

Earth terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THIS OVEN MUST BE EARTHED

The cable used to connect the oven to the electrical supply must comply to the specifications given below.

For Uk use only

Connection

Min. size

Cable / flex

Fuse

via

Cable/flex

type

 

 

 

 

 

 

 

 

• 13 A socket

2.5 mm2

3 core

13 A

outlet

 

 

butyl

min.

• 13 A

 

 

insulated

 

 

spur box

 

 

 

 

 

 

 

 

 

 

 

• Cooker

2.5 mm2

PVC/PVC

15 A min.

Control

 

 

twin and

20 A max.

Circuit

 

 

earth

 

 

For Europe use only

 

 

 

 

 

 

 

Min. size Cable/flex

Cable / flex type

 

Fuse

 

 

 

 

 

1.5 mm2

 

H05 RR-F

 

13 A

 

 

 

 

 

 

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a tempera- ture of more than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.

The manufacturer disclaims any responsibility should these safety measures not be carried out.