Zanussi ZBS863 Installation, Electrical Connection, Technical Data, Heating elements rating, Fuse

Models: ZBS863

1 24
Download 24 pages 39.65 Kb
Page 19
Image 19
Installation

Installation

The oven must be installed according to the instructions supplied.

This oven must be installed by qualified personnel to the relevant British Standards.

Technical Data

 

Heating elements rating

1,800 W

Dimensions of recess

 

Oven elements

 

Top element

800 W

Height

580 mm

Bottom element

1,000 W

Width

560 mm

Depth

550 mm

Convection element

2,000 W

 

 

Inner Grill element

1,650 W

Dimensions of the oven cavity

 

Double Grill element

2,450 W

Height

335 mm

Thermal grilling

2,450 W

Width

395 mm

Oven Light

25 W

Depth

400 mm

Cooling Fan

25 W

Oven capacity

53 litres

Convection Fan

25 W

 

 

 

 

Total Rating

2,500 W

 

 

Supply voltage (50 Hz)

230 V

Electrical Connection

 

The oven is designed to be connected to 230 V (50 Hz) electricity supply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

 

 

 

 

 

 

 

or E

-

Earth terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The oven must be installed according to the instructions supplied. THIS OVEN MUST BE EARTHED

The cable used to connect the oven to the electrical supply must comply to the specifications given below.

For Uk use only

Connection
Min. size
Cable / flex
Fuse

via

Cable/flex
type

 

• 13 A socket

2.5 mm2

3 core

13 A

outlet

 

butyl

min.

• 13 A

 

insulated

 

spur box

 

 

 

 

 

 

 

• Cooker

2.5 mm2

PVC/PVC

15 A min.

Control

 

twin and

20 A max.

Circuit

 

earth

 

For Europe use only

Min. size Cable/flex
Cable / flex type

Fuse

 

 

 

1.5 mm2

H07 RN-F, H05 RN-F,

13 A

 

H05 RR-F, H05 VV-F,

 

 

H05 V2V2-F (T90),

 

 

H05 BB-F

 

 

 

 

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

The yellow and green earth cable should be 2-3 cm longer than the other cables.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.

Themanufacturerdisclaimsanyresponsibilityshould these safety measures not be carried out.

19

Page 19
Image 19
Zanussi ZBS863 Installation, Electrical Connection, Technical Data, Heating elements rating, Dimensions of recess, Fuse