ELECTRICAL CONNECTION

We strongly recommend that all operations for the installation of your oven be carried out by QUALIFIED PERSONNEL to the relevant British Standards.

The oven designed to be connected to 240V (50Hz) electricity supply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

 

 

 

 

 

 

 

 

-

Earth terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THIS APPLIANCE MUST BE EARTHED

The cable used to connect the oven to the electrical supply should have the characteristics indicated in the table.

It is necessary that you install a double pole switch between the appliance and theelectricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient temperature.

Before the appliance is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.

The manufacturer disclaims any responsibility should these safety measures not be carried out.

This appliance meets the requirements laid down in EEC Directive No. 89/336 relating to the suppression of radio and TV interference.

For Uk use only

Models

Rating

Cable cross

Fuse

 

 

section mm2 and

 

 

 

Type of the cable

min.

 

 

 

 

ZBS 701

2870 W

6 mm2

 

 

 

6242 Y

15 A

 

 

 

 

For Europe use only

Models

Rating

Cable cross

Fuse

 

 

section mm2 and

 

 

 

Type of the cable

min.

 

 

 

 

ZBS 701

2870 W

2,5 mm2

 

 

 

Ho5 RR-F

13 A

 

 

 

 

9

Page 8