Zanussi ZCG 6200 Installation Instructions, Technical Data, Z C G, Dimensions, Connections, Grill

Models: ZCG 6200

1 40
Download 40 pages 44.5 Kb
Page 31
Image 31
INSTALLATION INSTRUCTIONS

Z C G 6 2 0 0

INSTALLATION INSTRUCTIONS

TECHNICAL DATA

DIMENSIONS

 

Height

 

Width

 

Depth

Height to hotplate

900mm (nominal)

500mm (nominal)

600mm

 

 

 

 

 

(to front of

 

 

 

 

 

door panel)

Space for fixing at hotplate level

2mm minimum clearance

 

 

Space for fixing above hotplate level

See important note 'Location of Appliance' page 33.

Minimum space above hotplate

787mm (If a cooker hood is fitted refer to the cooker hood

 

installation instructions).

 

 

Weight of appliance

52.5kg.

 

 

 

 

Minimum distance from rear wall

5mm (spacer given by pressed spacer on vent panel).

CONNECTIONS

 

 

 

 

 

Gas

Rear left hand side of appliance at hotplate level.

 

 

Rc½ (½" B.S.P. female).

 

 

Electric

None

 

 

 

 

IGNITION

 

 

 

 

 

Spark generator

APCO 6BG 6893

 

 

 

Battery

1.5 Volt AA size

 

 

 

 

GRILL

Natural Gas

 

 

L.P. Gas

 

Heat Input

3.3kW (11263 Btu/h)

3.0kW (215g/h)

Injector Marking

138

 

 

88

 

HOTPLATE

 

 

Natural Gas

 

 

 

R.H.F.

 

R.H.R.

L.H.R.

L.H.F

Heat Input

1.0kW

 

2.0kW

2.0kW

2.8kW

 

(3412 Btu/h)

(6824 Btu/h)

(6824 Btu/h)

(9554 Btu/h)

Injector Marking

079

 

104

104

130

 

 

 

L.P. Gas

 

 

Heat Input

1.0kW

 

2.0kW

2.0kW

2.7kW

 

(71.8 g/h)

 

(143.7 g/h)

(143.7 g/h)

(194.0 g/h)

Injector Marking

051

 

072

072

083