Zanussi ZCM 1000X Technical Details, EMC Directive 89/336/EEC CE Marking Directive 93/68/EEC

Models: ZCM 1000X

1 24
Download 24 pages 10.88 Kb
Page 15
Image 15
TECHNICAL DETAILS

TECHNICAL DETAILS

Loading info : Gas hotplate

Natural gas

 

 

L.H.F. – Simmer -

 

1.0 Kw ( 3412 Btu/h )

Injector marking

 

070

L.H.R. / R.H.R. – Normal-

1.8 Kw ( 6142 Btu/h )

Injector marking

 

096

R.H.F. – Rapid -

 

2.8 Kw ( 9554 Btu/h )

Injector marking

 

119

Centre. – Ultra Rapid -

3.5Kw ( 11942 Btu/h )

Injector marking

 

136

Physical Characteristics –

 

Height:

 

940 mm

Width:

 

1050 mm

Depth:

 

600 mm

(excluding handles)

 

 

Weight:

 

100 Kg Net

Gas connection

:-

Rear right hand side of appliance at hotplate level

 

 

Rc ½ (½” B.S.P. female )

Electrical connection :-

230 / 240 V 50 Hz mains 3 cable is supplied with an integral, moulded plug fitted

 

 

with a 3 amp fuse.

GAS CATERGORY

COUNTRIES OF DESTINATION

CAT. I2H

 

GB, IE

CAT. I3+

 

GB, IE

This appliance complies with: European Council Directive 73/23/EEC.

EMC Directive 89/336/EEC.

CE Marking Directive 93/68/EEC.

15

Page 15
Image 15
Zanussi ZCM 1000X manual Technical Details, This appliance complies with European Council Directive 73/23/EEC