1 2

1.Open the small door at the

2. Turn the yellow stop

3. Pull out the reservoir.

lower part of the cabinet.

upwards.

 

 

 

4.Open the small cover and let water flow down.

Close the small cover and re-insert the reservoir cor- rectly.

1

2

5.Push it until it clicks and turn the yellow stop down- wards ensure it is firmly locked.

6.Close the small door and press the START/PAUSE button again to allow the programme to continue.

Important:

The reservoir must be re- inserted correctly.

After emptying and inserting the reservoir the START-but- ton has to be depressed again to allow the pro- gramme to continue.

Handy tip: The condensed water may be used in a steam iron or to top up a battery, etc. In this case it must be filtered (e.g. through a coffee filter).

Cleaning the air intake grille

Using a vacuum cleaner remove the fluff from the air intake grille at the back of the appliance.

Cleaning the drum

When your laundry does not reach the desired degree of dryness, in other words, when it turns out either too dry or too damp, we advise you to clean the inside of the drum with a cloth soaked with vinegar.

This will eliminate the slight patina that has formed in the drum (due to residues of detergent and softeners used in the wash- ing, and to the lime contained in the water), which prevents the probes from detecting the correct degree of dryness.