Hints for test centres
Testing in accordance with | EN 60704 must be carried out with appliance fully loaded and using the test programme (see "Washing | |
programmes" chart). |
|
|
Test in accordance with | EN 50242 | must be carried out when the salt container and rinse aid dispenser have been filled with salt and |
rinse aid respectively and using the test programme (see "Washing programmes" chart).
Load: | 12 standard place settings |
|
|
Rinse aid setting: | position 4 (Type III) |
|
|
Detergent dosage : | 5 g + 25 g (Type B) |
|
|
Arrangement upper basket
Arrangement lower basket
Arrangement cutlery basket
Cup racks: position A
21