Zanussi ZGF 647 installation manual Building In, Sr A Sr R

Models: ZGF 647

1 16
Download 16 pages 23.84 Kb
Page 10
Image 10
9. Building In

BURNERS

TYPE

TYPE OF

INJECTORS

NOMINAL

REDUCED

NOMINAL

NOMINAL

OF GAS

BURNER

MARKS

POWER

POWER

POWER

PRESSURE

 

 

1/100 mm

INPUT

kW

 

 

mbar

 

 

m3/h

 

 

 

 

KW

 

g/h

 

NATURAL

Rapid (large)

115

2,3

0,575

0,064

-

 

Semi-rapid (medium)

96

1,6

0,400

0,044

-

20

GAS

Auxiliary (small)

64

0,7

0,230

0,019

-

 

GZ 50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LPG

Rapid (large)

75

2,1

0,525

-

46

 

(Buthane/

Semi-rapid (medium)

60

1,5

0,375

-

33

36

Propane)

Auxiliary (small)

41

0,7

0,230

-

15

 

 

 

 

 

 

 

 

 

 

 

TOWN

Rapid (large)

180

2,3

0,575

0,089

-

 

GAS

Semi-rapid (medium)

150

1,6

0,400

0,062

-

13

GZ 35

Auxiliary (small)

95

0,7

0,230

0,027

-

 

 

 

 

 

 

 

 

 

9. Building In

SR

A

SR

R

580 SRManual backgroundManual background

A = Auxiliary burner

SR = Semirapid burner

R = Rapid Burner

These hobs can be inserted in a built-in kitchen unit whose depth is between 550 and 600 mm. The hobs dimensions are shown in Fig. 10.

510

Fig. 10

10

Page 10
Image 10
Zanussi ZGF 647 installation manual Building In, Sr A Sr R