Something Not Working?
If the appliance is not working correctly, please carry out the following checks before contacting your local Service Centre.
SYMPTOM | SOLUTION |
There is no spark when lighting the gas | Check that the unit is plugged in and the |
| electrical supply is switched on |
| Check that the RCCB has not tripped (if |
| fitted) |
| Check the burner cap and crown have been |
| replaced correctly, e.g. after cleaning. |
The gas ring burns unevenly | Check the main jet is not blocked and the |
| burner crown is clear of food particles. |
| Check the burner cap and crown have been |
| replaced correctly, e.g. after cleaning. |
|
|
If after all these checks, your appliance still does not operate correctly, contact your local Service Centre.
Instructions for the Installer
Engineers technical data
OVERALL DIMENSIONS
Width: 580 mm
Depth: 510 mm
Height: 88 mm
Weight: 12,5 Kg
Supply Connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
CUT OUT DIMENSIONS
Width: | 550 mm |
|
|
| Appliance Gas supply: LPG 30 mbar | |||||||
|
|
|
|
|
|
|
|
| ||||
Depth: | 470 mm |
|
|
| Appliance Class: 3 |
|
| |||||
Thickness: 30 mm |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| Appliance category: I 3 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |
| Burner |
|
| Nominal Power | LPG (Butane "A") | Diameter |
| Feeding |
| |||
|
|
|
|
|
|
|
|
| Tap. |
| Pressure |
|
|
|
|
| kW | kCal/h | Nozzle |
| gh |
|
| mbar (*) |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Auxiliary (dia. 42 mm.) | 0,95 | 814 | 50 |
| 75 | 28 |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
| 1,60 | 1368 | 65 |
| 126 | 35 |
| 30 |
| |||
|
|
|
|
|
|
|
|
|
|
| ||
| Rapid (dia. 90 mm.) | 2,45 | 2095 | 80 |
| 193 | 45 |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
(*) 1 mbar = 10 mm. water coloumn.
7