•Ensure that the cover is securely fastened.
Note: House circuit
Earth leakage / continuity tests must be carried out before the appliance is connected to the mains supply and
WARNING!
Connecting to gas supply
•This appliance is designed to be installed with an appliance flexible connection only.
•Supply piping should not be less than R3/8. Connection is made to the Rc ½ (½” B.S.P.) female threaded entry pipe located just below the hob level on the rear left hand side of the appliance.
IMPORTANT!
ONLY LIQUID SEALANTS TO BE USED WHEN INLET GAS PIPE IS FITTED I.E.: DO NOT USE P.T.F.E. SEALANT TAPE.
•Carry out a gas tightness test after connecting to the gas supply.
•The gas bayonet connector must be fitted in the shaded area indicated.
•Take into account that it must be possible to pull the appliance forward sufficiently. Ensure the hose does not become trapped when pushing the appliance into position.
IMPORTANT!
FLEXIBLE TUBING USED MUST COMPLY WITH BS.669 CURRENT EDITION.
Fitting the stability chain
It is recommended that if the appliance is to be installed with a flexible supply pipe, a stability chain be fitted and is available from your supplier (see Important Safety Requirements). These instructions should be read in conjunction with any leaflet packed with the stability chain.
39