Check and clean the spark plug. Adjust the electrode gap to .024~.028in (0.6~0.7mm) if necessary.

.024 ~ .028 in (0.6~0.7mm)

Replacement plug: NGK BPMR7A

INSPECTION EVERY 100 HOURS

The muffler is equipped with a spark arrester to prevent red hot carbon from flying out of the exhaust outlet. In the State of California it is required by law (Section 4442 of the California Public Resources Code) to equip a spark arrester when a gas powered tool is used in any forest covered, brush covered, or grass covered unimproved land.

Speak

Arrester

Check and tighten each fastener.

Dismount the engine and check the clutch system to see if oil is observed between the clutch lining and its drum. If any, wipe it off with gasoline.