9. Troubleshooting guide

Case 1. Starting failure

 

 

 

CHECK

PROBABLE CAUSES

ACTION

 

fuel tank

incorrect fuel

drain it and use correct fuel

 

fuel filter

fuel filter is clogged

clean

 

carburetor adjustment screw

out of normal range

adjust to normal range

 

sparking (no spark)

spark plug is fouled/wet

clean/dry

 

 

plug gap is incorrect

correct (GAP: 0.6 ~ 0.7 mm)

 

 

 

 

 

spark plug

disconnected

retighten

Case 2. Engine starts but does not keep running/hard re-starting

 

 

CHECK

PROBABLE CAUSES

ACTION

 

fuel tank

incorrect fuel or staled fuel

drain it and use correct fuel

 

carburetor adjustment screw

out of normal range

adjust to normal range

 

muffler, cylinder (exhaust port)

carbon is built-up

wipe away

 

air cleaner

clogged with dust

wash

 

cylinder fin, fan cover

clogged with dust

clean