Zenoah GZ50N owner manual Storage, Disposal, Muffler, Intake AIR Cooling Vent

Models: GZ50N

1 9
Download 9 pages 57.89 Kb
Page 7
Image 7

GZ50N

6. Maintenance

MUFFLER

WARNING

Inspect periodically, the muffler for loose fasten- ers, any damage or corrosion. If any sign of ex- haust leakage is found, stop using the machine and have it repaired immediately.

Note that failing to do so may result in the engine catching on fire.

INTAKE AIR COOLING VENT

WARNING

Never touch the cylinder, muffler, or spark plugs with your bare hands immediately after stopping the engine. The engine can become very hot when in operation, and doing so could result in severe burns.

When checking the machine to make sure that it is okay before using it, check the area around the muffler and remove any wood chips or leaves which have attached themselves to the brushcutter. Failing to do so could cause the muf- fler to become overheated and that in turn could cause the engine to catch on fire. Always make sure that the muffler is clean and free of wood chips, leaves, and other waste before use.

Check the intake air cooling vent and the area around the cylinder cooling fins after every 25 hours of use for blockage, and remove any waste which has attached itself to the brushcutter. Note that it is necessary to remove the upper cover and the lower cover shown in in order to be able to view the upper part of the cylinder.

IMPORTANT

If waste gets stuck and causes blockage around the intake air cooling vent or between the cylinder fins, it may cause the engine to overheat, and that in turn may cause mechanical failure on the part of the en- gine.

(1)

(1) Cylinder

PROCEDURES TO BE PERFORMED AFTER EVERY 100 HOURS OF USE

1.Remove the muffler, insert a screwdriver into the vent, and wipe away any carbon buildup. Wipe away any carbon buildup on the muffler exhaust vent and cylin- der exhaust port at the same time.

2.Tighten all screws, bolts, and fittings.

3.Check to see if any oil or grease has worked its way in between the clutch lining and drum, and if it has, wipe it away using oil-free, lead-free gasoline.

G B

7. Storage

Aged fuel is one of major causes of engine starting fail- ure. Before storing the unit, empty the fuel tank and run the engine until it uses all the fuel left in the fuel line and the carburetor. Store the unit indoor taking necessary measures for rust prevention.

8. Disposal

When disposing your machine, fuel or oil for the machine, be sure to allow your local regulations.

GB-7

Page 7
Image 7
Zenoah GZ50N Storage, Disposal, Muffler, Intake AIR Cooling Vent, Procedures to be Performed After Every 100 Hours of USE