F-14

TROUBLESHOOTING & REPAIR

F-14

 

 

CONTROL TRANSFORMER (T2) VOLTAGE TEST

FIGURE F.1 - Control Transformer Lead Location

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

1.Disconnect main AC input power to the machine.

2.Remove the Top and Case Sides.

3.Locate the Control Transformer (T2) on the left side of the Input Box (fac- ing the back of the machine). See Figure F.1.

4.Locate the Control Transformer primary leads (H1, H2, H3, etc.). See wiring diagram.

NOTE: Unused leads should be taped. Check for loose or faulty connections.

IDEALARC DC-1000

Page 54
Image 54
Lincoln Electric SVM123-A service manual Test Procedure, Figure F.1 Control Transformer Lead Location