Lincoln Electric SVM123-A service manual Perform SCR Output Bridge

Models: SVM123-A

1 113
Download 113 pages 14.33 Kb
Page 47
Image 47

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-7

TROUBLESHOOTING & REPAIR

F-7

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

Machine has maximum weld out-

1. If remote control is being

1.

Check output control switch

put and no control.

 

used, put output control switch

 

(SW3) and associated wiring.

 

 

(SW3) in “OUTPUT CON-

 

 

 

 

 

TROL AT DC-1000” position

2.

Check feedback leads #222

 

 

and control weld output with

 

(negative output terminal) and

 

 

the output control (R1) at DC-

 

#215, #210(output shunt) for

 

 

1000. If the problem is solved,

 

loose or faulty connections.

 

 

check the remote control unit

 

See wiring diagram.

 

 

 

(or wire feeder) and associat-

 

 

 

 

 

ed control cable.

3.

Check the #75 lead for conti-

 

 

 

 

nuity (zero ohms) from the

 

 

 

 

output control potentiometer

 

 

 

 

(R1) to the control board plug

 

 

 

 

10J1. See wiring diagram.

 

 

 

4. Perform Firing Board Test.

 

 

 

5. Perform Control Board Test.

 

 

 

6. Perform SCR Output Bridge

 

 

 

 

Test.

 

 

 

 

 

 

Machine has minimum output

1. If a remote control unit is NOT

1.

Check the output

control

and no control.

 

connected to the terminal strip

 

potentiometer (R1) and asso-

 

 

#73, #74,#75, #76, and/or #77

 

ciated wiring.

 

 

 

terminals, the output control

 

 

 

 

 

switch must be in the “OUT-

2.

Check the output

control

 

 

PUT CONTROL AT DC-1000”

 

switch (SW3) the welding

 

 

position.

 

mode switch (SW4) and asso-

 

 

 

 

ciated wiring.

 

 

 

2. If a remote control cable is

 

 

 

 

 

connected to terminals #73,

3.

Perform the Control Board

 

 

#74, #75, #76, and/or #77, the

 

Test.

 

 

 

leads may be shorted to the

 

 

 

 

 

positive weld output.

4.

Perform the Firing Board

 

 

 

 

Test.

 

 

 

3. Make certain the three phase

 

 

 

 

 

input voltage is correct and

5.

Perform the SCR Output

 

 

matches the machine rating

 

Bridge Test..

 

 

 

and the reconnect panel.

 

 

 

 

 

 

6.

Perform Main Transformer

 

 

 

 

Test.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

IDEALARC DC-1000

Page 47
Image 47
Lincoln Electric SVM123-A service manual Perform SCR Output Bridge