Lincoln Electric SVM123-A service manual Troubleshooting & Repair

Models: SVM123-A

1 113
Download 113 pages 14.33 Kb
Page 81
Image 81

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-41

TROUBLESHOOTING & REPAIR

F-41

 

 

TYPICAL OUTPUT VOLTAGE WAVEFORM -MACHINE LOADED CONSTANT VOLTAGE INNERSHIELD MODE

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

This is the typical DC open circuit volt- age waveform generated from a proper- ly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 2 milliseconds in time. The machine was loaded with a resistance grid bank. The grid bank meters read 600 amps at 44 VDC.

Note: Scope probes connected at

machine ouput terminals: (+) probe to positive 1000 Amp terminal, (-) probe to negative terminal.

SCOPE SETTINGS

Volts/Div. . . . . . . . . . . . . 20 V/Div. Horizontal Sweep . . . . . 2 ms/Div. Coupling . . . . . . . . . . . . . . . . . DC Trigger . . . . . . . . . . . . . . . Internal

IDEALARC DC-1000

Page 81
Image 81
Lincoln Electric SVM123-A service manual Troubleshooting & Repair