REASSEMBLY OF LIFT BAIL

1.Place the lift bail onto the IDE- ALARC DC-1000 from the top, low- ering straight onto the unit.

2.Using a 9/16” socket wrench, attach the four bolts and associated wash- ers mounting the lift bail to the base assembly.

3.Using a 9/16” socket wrench, attach the four bolts mounting the lift bail to the main transformer assembly.

4.Using a 3/8” socket wrench, attach the two screws holding the input contactor bracket to the lift bail.

5.Reattach leads #217 and #222 to resistor R2.

6.Reattach or reconnect any cables or wire ties previously removed.

7.Using a 5/16 (8mm) nut driver or flat head screw driver, attach 20 screws (ten per side) to secure case sides, and 2 screws to secure top.