F-9

TROUBLESHOOTING & REPAIR

F-9

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

 

Machine shuts off (input contac-

1. Remove all welding cables

1. Check for grounds and or

tor drops out) when the welder

and control cables from the

 

shorts in the #73, #74, #75,

output terminals are electrically

DC-1000. Jumper #2 to #4 at

 

#76, #77 circuit. See wiring

energized. (#2 to #4 closure at

the terminal strip. If the

 

diagram.

 

terminal strip.)

machine does NOT shut off

 

 

 

 

 

and normal open circuit volt-

2.

Check for grounds and shorts

 

 

age is present at the welder

 

in the welder output terminals

 

 

output terminals, the problem

 

and associated leads. See

 

 

is external to the DC-1000.

 

wiring diagram.

 

 

 

Either the remote leads #73,

 

 

 

 

 

#74, #75, #76 or #77 are

3.

Check the output shunt and

 

 

grounded to the negative out-

 

associated leads. See wiring

 

 

put cable, or there is a short

 

diagram.

 

 

 

on the welding output termi-

 

 

 

 

 

nals.

4. Perform the Control Board

 

 

 

 

Test.

 

 

 

2. If the machine still shuts off

 

 

 

 

 

when all control and welding

 

 

 

 

 

cables are removed, then the

 

 

 

 

 

problem is internal to the DC-

 

 

 

 

 

1000.

 

 

 

 

 

 

The DC-1000 will NOT shut off

1. Contact your local Lincoln

1. The input contactor (1CR)

when the Stop button is pushed.

Authorized Field Service

 

contacts may be stuck closed.

 

 

Facility.

 

Check and replace if neces-

 

 

 

 

sary.

 

 

 

 

2. The Interlock contacts (part of

 

 

 

 

1CR) may be faulty. Replace

 

 

 

 

if necessary.

 

 

 

 

3. The Start/Stop button may be

 

 

 

 

faulty. Check or replace.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

IDEALARC DC-1000