F-56

TROUBLESHOOTING & REPAIR

F-56

 

REMOVAL AND REASSEMBLY OF LIFT BAIL

FIGURE F.25 - Lift Bail Removal

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

REMOVAL OF LIFT BAIL

1.Remove input power to machine.

2.Using a 5/16 (8mm) nut driver or flat head screw driver, remove 20 screws (ten per side) to remove case sides and 2 screws to remove top.

3.Remove two leads, #217 and #222 from resistor R2.

4.Using a 3/8” socket wrench, remove the two screws holding the input contactor bracket to the lift bail.

5.Using a 9/16” socket wrench, remove the four bolts mounting the lift bail to the main transformer assembly.

6.Using a 9/16” socket wrench, remove the four bolts and associat- ed washers mounting the lift bail to the base assembly. See Figure F.25.

7.Loosen or remove any cable or wire ties necessary for lift bail removal.

8.Carefully remove the lift bail by lift- ing straight up and clear.