TROUBLESHOOTING & REPAIR

F-47

 

 

INPUT CONTACTOR (1CR) CLEANING AND/OR REPLACEMENT

Return to

Return to Section TOC

Return to Section TOC

Return to

Return to Master TOC

Return to Master TOC

WARNING

DO NOT APPLY INPUT POWER TO THE DC-1000 WITH THE CONTACTOR

COVER PLATE

REMOVED. POWER

APPLIED WITHOUT

COVER PLATE IN POSITION MAY CAUSE SEVERE ARCING RESULTING IN BODILY INJURY.

________________________________________

3.Blow out any dirt or dust from in and around contacts.

4.Examine contacts for signs of wear.

5.If contacts are stuck together or overheated, parts of the contactor, or the entire assembly, should be replaced.

CONTACTOR REPLACEMENT

REMOVAL

1.Using a 11/16” wrench, remove leads L1, L2, L3 and output power leads from 1CR contactor. Mark and label all leads for proper recon- nection. See Figure F.19.

2.Remove lead #257 at secondary thermostat. See Figure F.20 and refer to Wiring Diagram. Remove any cable ties and/or harness looms as necessary.

3.Remove the contactor interlock leads from quick disconnects (leads 211 and 212) and from resistor R3. See Figure F-21 and refer to Wiring Diagram.

4.Remove input contactor using a 7/16” socket wrench. Remove the four mounting bolts, nuts, and asso- ciated washers (or loosen the two bottom bolts and nuts, and remove the top two).

Return to Section TOC

Return to Master TOC

FIGURE F.20 - Lead #257 at

FIGURE F.21 - Lead #211 and #212

Secondary Thermostat

Quick Disconnects