TROUBLESHOOTING & REPAIR | ||
|
|
RETEST AFTER REPAIR
Testing is required after the removal of any mechanical part that could affect the machine’s electrical characteristics, or if any electrical components are repaired or replaced.
INPUT IDLE AMPS AND WATTS
Input Volts/Phase/Hertz | Maximum Idle Amps | Maximum Idle KW |
|
|
|
230/3/60 | 14.0 | 2.0 |
460/3/60 | 7.0 | 2.0 |
575/3/60 | 5.6 | 2.0 |
|
|
|
OPEN CIRCUIT VOLTAGES
Mode | Input Hertz | Open Circuit Volts |
|
|
|
Variable Voltage | 60 | 74/76 DC |
Auxiliary Output | 60 | 122/124 AC |
|
|
|
MAXIMUM ACCEPTABLE OUTPUT VOLTAGE - AT MINIMUM OUTPUT
SETTINGS
Mode | Input Hertz | Load |
|
|
|
Constant Voltage Innershield | 60 | 140 Amps @ 14/18 VDC |
|
|
|
MINIMUM ACCEPTABLE OUTPUT VOLTAGE AT MAXIMUM OUTPUT
SETTINGS
Mode | Input Hertz | Load |
|
|
|
Variable Voltage | 60 | 1250 Amps @ 47/52 VDC |
Constant Voltage Submerged Arc | 60 | 1250 Amps @ 47/52 VDC |
Constant Voltage Submerged Arc | 60 | 625 Amps @ 53/58 VDC |
at 500 Amp Terminal |
|
|
|
|
|