Lincoln Electric SVM123-A service manual Possible Problems Pertaining to the Control Board

Models: SVM123-A

1 113
Download 113 pages 14.33 Kb
Page 67
Image 67

TOC

TOC

F-27

TROUBLESHOOTING & REPAIR

F-27

 

 

CONTROL BOARD TEST

Return to Section

Return to Section TOC

Return to Section TOC

Return to Master

Return to Master TOC

Return to Master TOC

POSSIBLE PROBLEMS PERTAINING TO THE CONTROL BOARD

IF LED 1 does not light, when the start switch is ON.

1.Check for 115 VAC at leads #255 to #256 plug J1

a.If the correct voltage is not present, check leads #255 and #256 and associated wiring for loose or faulty connections. See wiring dia- gram and Figure F.10.

b.Remove main supply power to the DC-1000. Test for continuity (zero ohms) from lead #255 plug J1 at the Control Board to lead #212 at the Start/Stop Button.

c.Test for continuity (zero ohms) from lead #256 plug J1 at the Control Board to the pilot light. See wiring dia- gram.

d.If the 115 VAC is present at leads #255 to #256 at plug J1 and LED 1 does not light, the Control Board may be faulty. Replace.

Return to Section TOC

Return to Master TOC

FIGURE F.10 - LED 1 Test Points

IDEALARC DC-1000

Page 67
Image 67
Lincoln Electric SVM123-A service manual Possible Problems Pertaining to the Control Board