F-29

TROUBLESHOOTING & REPAIR

F-29

 

 

CONTROL BOARD TEST

Return to Section

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master

Return to Master TOC

Return to Master TOC

Return to Master TOC

IF LED 3 does not light when the

Start Button is depressed (but LED 1 does light).

The Fault Protection Relay (2CR) is not receiving supply voltage (24 VDC) and the Input Contactor (1CR) will not stay closed. Check to see if LED 4 lights or “flickers” when the Start Button is held in.

If LED 4 lights,

1.There may be a “short” at the welder output terminals or the remote control circuit (leads #73, #74, # 75, #76 and #77) may be shorted to the negative welding voltage. Check the weld output ter- minals and associated leads and also the remote control circuitry. See wiring diagram.

2.If the above procedures do not reveal the problem, then the Control board may be faulty- Replace.

IF LED 5 does not light and varies in brightness when #2 and #4 are jumpered together, while the Output Control Potentiometer is rotated .

The Control Board may be faulty- Replace.

NOTE: The Weld Mode Switch (SW4) must be in the CV position and the Output Control Switch (SW3) in the “Output Control at DC-1000” position. Also check the Output Control Potentiometer and associated circuitry.

IDEALARC DC-1000

Page 69