A-3

INSTALLATION

A-3

 

 

 

 

Read entire Installation Section before installing

 

 

 

 

 

 

the IDEALARC DC-1000.

STACKING HOLE

SAFETY PRECAUTIONS

 

 

 

 

 

 

 

 

 

WARNING

 

 

 

ELECTRIC SHOCK CAN KILL.

 

 

 

 

• Only qualified personnel should install this

 

 

 

 

machine.

 

 

 

 

• Turn the input power OFF at the discon-

 

 

 

 

nect switch or fuse box before installing or

 

 

 

 

working on the equipment.

STACKING PIN

 

 

• Do not touch electrically hot parts.

Always connect the IDEALARC DC-1000 grounding terminal to a good electrical earth ground.

____________________________________________________

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

SELECT PROPER LOCATION

Place the IDEALARC DC-1000 where clean, dry air can freely circulate in through the front intake and out through the rear louvers. Dirt, dust, or any foreign material that can be drawn into the machine should be kept at a minimum. Not following these precautions can result in the nuisance shutdown of the machine because of excessive operating temperatures.

STACKING

WARNING

FALLING EQUIPMENT can

cause injury.

Do not lift this machine using lift bale if it

is equipped with a heavy accessory such as trailer or gas cylinder.

• Lift only with equipment of adequate lifting capacity.

Be sure machine is stable when lifting.

Do not stack more than two high.

Do not stack the DC-1000 on top of any other machine.

____________________________________________________

Two IDEALARC DC-1000 machines can be stacked.

Follow these guidelines when stacking:

1.Select a firm, level surface capable of supporting the total weight of two machines (1642 pounds/744 kilograms).

2.Set the bottom machine in place.

3.Stack the second machine on top of it by aligning the two holes in the base rails of the second machine with the two pins on top front of the bot- tom machine.

NOTE: The machines must be stacked with the Case Front of each machine flush with each other. See Figure A.1.

FIGURE A.1 - Stacking IDEALARC DC-1000

Machines

TILTING

The IDEALARC DC-1000 must be placed on a stable, level surface so it will not topple over.

ELECTRICAL INPUT

CONNECTIONS

Before installing the machine, check that the input supply voltage, phase, and frequency are the same as the machine’s voltage, phase, and frequency as spec- ified on the machine’s rating plate on the Case Front Assembly Control Panel. Connect input power supply by removing the rear access panel and connecting to the three line terminals on the input panel. See Figure A.2 for the location of the machine’s input cable entry opening and reconnect panel assembly for dual volt- age machines.

FIGURE A.2 - Input Power Supply Connection