F-38

TROUBLESHOOTING & REPAIR

F-38

 

 

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM

CONSTANT CURRENT MODE - NO LOAD

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

This is the typical DC open circuit volt- age waveform generated from a proper- ly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 2 milliseconds in time.

Note: Scope probes connected at

machine output terminals: (+) probe to positive 1000 Amp terminal, (-) probe to negative terminal.

SCOPE SETTINGS

Volts/Div. . . . . . . . . . . . . 50 V/Div. Horizontal Sweep . . . . . 2 ms/Div. Coupling . . . . . . . . . . . . . . . . . DC Trigger . . . . . . . . . . . . . . . Internal