TROUBLESHOOTING & REPAIR

F-8

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

Return

Return to Section TOC

Return to Section TOC

Return

Return to Master TOC

Return to Master TOC

The machine does not have max- imum weld output.

1.Check all three-phase input lines at the DC-1000. Make sure input voltages match machine rating and reconnect panel.

2.Put output control switch (SW3) in “OUTPUT CON- TROL AT DC-1000” position. If problem is solved, then check remote control unit or wire feeder.

1.Check the output control potentiometer (R1) and asso- ciated circuitry for loose or faulty connections. See wiring diagram.

2.Perform Control Board Test.

3.Perform Firing Board test.

4.Perform Main Transformer Test.

5.Perform SCR Output Bridge Test.

Return to Section TOC

Return to Master TOC

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.