B-4

OPERATION

B-4

 

 

• Three circuit solid state control system provides

• Enclosure designed with air intake louvers that

 

 

maximum performance and circuit protection.

keep dripping water from entering the unit, allow-

• Low profile case provides maximum use of space.

ing outdoor operation. Transformer, SCR bridge,

• Convenient access to all controls.

and choke have special corrosion resistant paint

• Large output lead strain relief openings to prevent

for added protection.

 

 

terminal and cable damage.

 

 

Easily removed case side, even when stacked.

WELDING CAPABILITY

The IDEALARC DC-1000 has the following duty cycle ratings.

If the duty cycle is exceeded, the thermal protective thermostat will shut off the output of the machine by keeping the input contactor open until the machine cools to normal operating temperature. The machine can then be restarted by pushing the ON/OFF push button.

Duty Cycle

Amps

Volts

Hertz

 

 

 

 

55% (Based on 10 min.)

1250

44

50/60

 

 

 

 

60% (Based on 10 min.)

1140

44

50/60

 

 

 

 

100%

1000

44

50/60

 

 

 

 

IDEALARC DC-1000

Page 20
Image 20
Lincoln Electric SVM123-A service manual Welding Capability