F-4

TROUBLESHOOTING & REPAIR

F-4

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

 

 

Major Physical or

Electrical

Contact the Lincoln Electric

 

 

 

Damage is Evident.

 

 

Service Dept. (216) 383-2531

 

 

 

 

 

 

or 1-800-833-9353 (WELD)

 

 

 

 

 

 

 

The Machine is dead - The Input

1. Check for blown or missing

1.

The.Start/Stop button (S1)

contactor does not

operate.

 

fuses in input lines.

 

may be faulty- Check for prop-

 

 

 

 

 

er operation. See wiring dia-

 

 

2.

Check the three-phase input

 

gram.

 

 

 

 

line voltage at the machine.

 

 

 

 

 

 

The input voltage must match

2.

The Control Transformer (T2)

 

 

 

the rating plate and reconnect

 

may be faulty. Perform the

 

 

 

panel.

 

Control Transformer Test.

 

 

 

 

3.

The primary or secondary

 

 

 

 

 

thermostats may be open.

 

 

 

 

 

Check or replace. Also check

 

 

 

 

 

the associated wiring. See

 

 

 

 

 

wiring diagram.

 

 

 

 

4.

The pilot relay (2CR) may be

 

 

 

 

 

faulty. Check or replace. See

 

 

 

 

 

wiring diagram.

 

 

 

 

5.

The input contactor coil may

 

 

 

 

 

be open. See wiring diagram.

 

 

 

 

6.

The Control board may be

 

 

 

 

 

faulty - Replace.

 

 

 

 

 

Input contactor (1CR) chatters.

1.

The input line voltage may be

1.

The pilot relay (2CR) may

 

 

 

low. Check all three phases.

 

have bad contacts. Check or

 

 

 

 

 

replace relay.

 

 

2. Make sure input line voltage

 

 

 

 

 

 

matches machine rating and

2.

Check for loose or faulty

 

 

 

reconnect panel.

 

wiring between pilot relay

 

 

 

 

 

(2CR) and input contactor

 

 

 

 

 

(1CR)

coil connections.

 

 

 

 

3.

The input contactor (1CR)

 

 

 

 

 

may be

faulty - Replace.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

IDEALARC DC-1000

Page 44
Image 44
Lincoln Electric SVM123-A service manual Control Transformer Test