Battery

This unit is of negative ground DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level are not properly maintained. Add only distilled water when replenishment is necessary.

DO NOT over fill. Check to see whether the battery cables are loose. Poor contact may result in poor starting or malfunctions. Always keep the terminals firmly tightened. Coating the terminals with an approved battery terminal treatment compound. Replace battery with only recommended type battery.

The battery is sufficiently charged if the specific gravity of the battery fluid is 1.28 (at 68° F). If the specific gravity should fall to 1.245 or lower, it indicates that the battery is dead and needs to be recharged or replaced.

Before charging the battery with an external electric source, be sure to disconnect the battery cables.

Battery Cable Installation

ALWAYS be sure the battery cables (Figure 37) are properly connected to the battery terminals as shown below.The Red Cable is connected to the positive terminal of the battery, and the Black Cable is connected to the negative terminal of the battery.

CAUTION - BATTERY SERVICING SAFETY

ALWAYS disconnect the negative terminal FIRST and reconnect negative terminal LAST.

Figure 37. Battery Connections

DCA-150SSJU3 — SETUP

When connecting battery do the following:

1.NEVER connect the battery cables to the battery terminals when the MPEC Control Switch is in either the MANUAL or AUTO position. ALWAYS make sure that the MPEC Control Switch is in the OFF/RESET position when connecting the battery.

2.Place a small amount of battery terminal treatment compound around both battery terminals.This will ensure a good connection and will help prevent corrosion around the battery terminals.

If the battery cable is connected

NOTE incorrectly, electrical damage to the generator will occur. Pay close attention to the polarity of the battery when connecting the battery.

CAUTION - BATTERY SERVICING SAFETY

Inadequate battery connections may cause poor starting of the generator, and create other malfunctions.

Alternator

The polarity of the alternator is negative grounding type. When an inverted circuit connection takes place, the circuit will be in short circuit instantaneously resulting the alternator failure.

DO NOT put water directly on the alternator. Entry of water into the alternator can cause corrision and damage the alternator.

Wiring

Inspect the entire generator for bad or worn electrical wiring or connections. If any wiring or connections are exposed (insulation missing) replace wiring immediately.

Piping and Hose Connection

Inspect all piping, oil hose, and fuel hose connections for wear and tightness.Tighten all hose clamps and check hoses for leaks.

If any hose (fuel or oil) lines are defective replace them immediately.

DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07) — PAGE 51

Page 51
Image 51
Multiquip DCA-150SSJU3 operation manual Battery Cable Installation, Alternator, Wiring, Piping and Hose Connection

DCA-150SSJU3 specifications

The Multiquip DCA-150SSJU3 is a powerful, reliable diesel generator that is designed to meet the demanding energy needs of various applications, including construction sites, events, and emergency power supply. With its robust construction and advanced technology, the DCA-150SSJU3 stands out in the competitive market of portable generators.

One of the main features of the DCA-150SSJU3 is its impressive output capabilities. This generator generates a continuous output of 150 kVA, which is more than enough to power multiple tools and equipment simultaneously. It is equipped with a high-quality, efficient diesel engine that not only delivers ample power but also ensures fuel efficiency, reducing operational costs over time.

The design of the DCA-150SSJU3 prioritizes user convenience and operational efficiency. It is fitted with a digital control panel that provides real-time monitoring of critical parameters such as voltage, frequency, and operating hours. This user-friendly interface simplifies the process of managing power output and helps operators maintain optimal performance.

Moreover, the DCA-150SSJU3 is equipped with advanced soundproofing technology, making it one of the quieter models in its class. This feature is particularly beneficial in environments where noise regulations must be adhered to, such as residential areas or during nighttime operations.

Durability is another key characteristic of the Multiquip DCA-150SSJU3. The generator is housed in a robust steel enclosure that protects it from external elements, ensuring longevity and reliable performance even in challenging conditions. Additionally, the generator has been designed with easy service access in mind, facilitating maintenance procedures and minimizing downtime.

Safety is paramount in generator design, and the DCA-150SSJU3 does not fall short in this aspect. It is equipped with a comprehensive range of safety features, including low oil shut-off, overload protection, and emergency stop buttons, ensuring safe operation for users.

In conclusion, the Multiquip DCA-150SSJU3 is a versatile and resilient diesel generator that excels in performance, efficiency, and safety. With its powerful output, advanced technologies, and user-friendly design, it is an ideal choice for those needing reliable power solutions across various demanding environments. Whether for temporary applications or as an emergency backup, the DCA-150SSJU3 is a generator that offers peace of mind and dependable performance.