Image 26
Active Fault Codes

DCA-150SSJU3 — DIAGNOSTIC DISPLAY

!Indicates Auxiliary Gage Fault

!Indicates Fault Warning

!Indicates Derate or Shutdown Condition Fault

5.Touching the “Enter Button” will redisplay the hidden fault. Touching the “Enter Button” once again will hide the fault and return the screen to the single or four parameter display. NOTE:The fault can only be cleared by correcting the cause of the fault condition.

1 of x

ENGINE OIL PRESSURE

GAGE NOT RESPONDING

HIDE

Active Fault Codes

1.During normal operation the single or four parameter screen will be displayed.

125°F

 

 

98%

1000 RPM

 

1000 RPM

 

 

 

LOAD RPM

ENG RPM

COOL TEMP

 

ENG RPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

143°F

 

 

 

 

 

 

 

 

57 PSI

14.2

57 PSI

OIL TEMP

 

 

 

BATT VOLT

OIL PRES

 

OIL PRES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.When the PowerView receives a fault code from an engine control unit the single or four parameter screen will be replaced with the “Active Fault Codes” message.

1 of x

WARNING

SPN110 FMI10

HIGH COOLANT TEMP

1000 RPM MOREManual background HIDE

3. If the word “MORE” appears above the “Arrow Buttons”, there are more active fault codes that may be viewed. Use the “Arrow Buttons” to scroll to the next “Active Fault Code”.

1 of x

SPN110 FMI10

HIGH COOLANT TEMP

Manual background MOREManual background HIDE

4.To acknowledge and “Hide” the fault and return to the single or four parameter display touch the “Enter Button”.

1 of x

SPN110 FMI10

HIGH COOLANT TEMP

Manual background MOREManual background HIDE

5.The display will return to the single or four parameter display but the display will contain the “Active Fault” warning icon.Touching the “Enter Button” will redisplay the hidden fault.

 

 

 

!

98%

 

1000 RPM

 

 

 

0

1500

3000

LOAD RPM

 

ENG RPM

 

 

1800 RPM

 

 

!

 

 

 

 

 

 

 

 

 

 

 

14.2

 

57 PSI

 

ENG RPM

COOL TEMP!

BATT VOLT

 

OIL PRES

!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.Touching the “Enter Button” once again will hide the fault and return the screen to the single or four parameter display.

1 of x

WARNING

SPN110 FMI10

HIGH COOLANT TEMP

Manual background MOREManual background HIDE

7.The Single or Four parameter screen will display the fault icon until the fault condition is corrected. NOTE: Ignoring active fault codes could result in severe engine damage.

 

 

 

 

 

 

 

GO TO 1-UP DISPLAY

98%

 

1000 RPM

STORED CODES

 

 

LOAD RPM

 

ENG RPM

ENGINE CONFG

 

 

 

!

 

SETUP 1-UP DISPLAY

 

 

 

 

 

 

 

 

SETUP-4-UP DISPLAY

14.2

 

57 PSI

SELECT UNITS

 

 

BATT VOLT

 

OIL PRES

ADJUST BACKLIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE 26 — DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07)

Page 26
Image 26
Multiquip operation manual Active Fault Codes, DCA-150SSJU3— DIAGNOSTIC DISPLAY, 1800 RPM, 1000 RPM