WET
HANDS

DCA-150SSJU3 — RULES FOR SAFE OPERATION

Generator Grounding

To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.

Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

The following safety recommendations should also be followed:

ALWAYS make sure generator is properly grounded.

NEVER use gas piping as an electrical ground.

DANGER - ELECTROCUTION HAZARDS

During operation of this generator, there exists the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even DEATH!

To avoid these hazards:

NEVER use damaged or worn cables when connecting equipment to the generator. Make sure power connecting cables are securely connected to the generator’s output terminals, insufficient tightening of the terminal connections may cause damage to the generator

and electrical shock.

ALWAYS make sure that electrical circuits are properly

grounded per the National Electrical Code (NEC) and

local codes before operating generator. Severe injury or

DEATH! by electrocution can result from operating an

ungrounded generator.

ALWAYS be sure to use the ground terminal (green wire)

when connecting a load to the U,V, and W output

terminal lugs.

Electrical Safety

ALWAYS have a qualified electrician perform the generator wiring installation.

ALWAYS make sure generator installation is accordance with the National Electrical Code (NEC) and local codes before operating generator.

NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper extension cord has been selected for the job. See Table 6.

NEVER power cables or cords lay in water.

NEVER stand in water while AC power from the generator is being transfer to a load.

NEVER grab or touch a live power cord with wet hands.

NEVER touch output terminals during operation. This is extremely dangerous. ALWAYS stop the machine and place the circuit breaker in the OFF position when contact with the output terminals is required.

Backfeed to a utility system can cause electrocution and or property damage. DO NOT connect to any building's electrical system except through an approved device or after building main switch is opened. ALWAYS have a licensed electrician perform the installation

POWER

CORD

(POWER ON)

DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07) — PAGE 11

Page 11
Image 11
Multiquip operation manual DCA-150SSJU3 Rules for Safe Operation, Generator Grounding, Electrical Safety

DCA-150SSJU3 specifications

The Multiquip DCA-150SSJU3 is a powerful, reliable diesel generator that is designed to meet the demanding energy needs of various applications, including construction sites, events, and emergency power supply. With its robust construction and advanced technology, the DCA-150SSJU3 stands out in the competitive market of portable generators.

One of the main features of the DCA-150SSJU3 is its impressive output capabilities. This generator generates a continuous output of 150 kVA, which is more than enough to power multiple tools and equipment simultaneously. It is equipped with a high-quality, efficient diesel engine that not only delivers ample power but also ensures fuel efficiency, reducing operational costs over time.

The design of the DCA-150SSJU3 prioritizes user convenience and operational efficiency. It is fitted with a digital control panel that provides real-time monitoring of critical parameters such as voltage, frequency, and operating hours. This user-friendly interface simplifies the process of managing power output and helps operators maintain optimal performance.

Moreover, the DCA-150SSJU3 is equipped with advanced soundproofing technology, making it one of the quieter models in its class. This feature is particularly beneficial in environments where noise regulations must be adhered to, such as residential areas or during nighttime operations.

Durability is another key characteristic of the Multiquip DCA-150SSJU3. The generator is housed in a robust steel enclosure that protects it from external elements, ensuring longevity and reliable performance even in challenging conditions. Additionally, the generator has been designed with easy service access in mind, facilitating maintenance procedures and minimizing downtime.

Safety is paramount in generator design, and the DCA-150SSJU3 does not fall short in this aspect. It is equipped with a comprehensive range of safety features, including low oil shut-off, overload protection, and emergency stop buttons, ensuring safe operation for users.

In conclusion, the Multiquip DCA-150SSJU3 is a versatile and resilient diesel generator that excels in performance, efficiency, and safety. With its powerful output, advanced technologies, and user-friendly design, it is an ideal choice for those needing reliable power solutions across various demanding environments. Whether for temporary applications or as an emergency backup, the DCA-150SSJU3 is a generator that offers peace of mind and dependable performance.