DCA-150SSJU3 — ENGINE OPERATING PANEL

9.Pre-Heat Lamp – When lit, indicates engine is in the pre-heating mode (for starting during cold weather operating conditiions). When lamp goes off engine is ready for starting.

10.Warning Lamp This lamp will illuminate when a critical engine fault has occured.

11.Emergency Stop Lamp This lamp will illuminate when the emergency stop button has been pressed or a critical engine fault has occured.

12.Diagnostic Display – This display monitors crtical engine functions. If any abnormal conditions occur, an Active Fault Code will be displayed. This diagnostic display can be located inside the control box.

13.Auto On/Off Engine Controller (MPEC) –

This controller has a vertical row of status LED's (inset), that when lit, indicate that an engine malfunction (fault) has been detected.When a fault has been detected the engine controller will evaluate the fault and all major faults will shutdown the generator.

During cranking cycle , The MPEC will attempt to crank the engine for 10 seconds before disengaging.

If the engine does not engage (start) by the third attempt, the engine will be shutdown by the engine controller’s Over Crank Protection mode. If the engine engages at a speed (RPM's) that is not safe, the controller will shutdown the engine by initializing the Over Speed Protection mode.

Also the engine controller will shut down the engine in the event of low oil pressure, high coolant temperature, low coolant level, and loss of magnetic pickup.These conditions can be observed by monitoring the LED status indicators on the front of the controller module.

A.MPEC Control Switch – This switch controls the running of the unit. If this switch is set to the OFF/RESET position, the unit will not run. When this switch is set to the MANUAL position, the generator will start immediately.

If the generator is to be connected to a building’s AC power source via an automatic transfer switch (isolation), place the switch in the AUTO position. In this position, should an outage occur, the automatic transfer switch (ATS) will start the generator automatically via the generator’s auto-start contacts connected to the ATS’s start contacts. Please refer to your ATS installation manual for further instructions for the correct installation of the auto-start contacts of the generator to the ATS.

B.Low Oil Pressure – Indicates the engine pressure has fallen below 15 psi. The oil pressure is detected using variable resistive values from the oil pressure sending unit. This is considered a major fault.

C.High Coolant Temperature – Indicates the engine temperature has exceeded 239°F. The engine temperature is detected using variable resistive values from the temperature sending unit. This is considered a major fault.

D.Overcrank Shutdown – Indicates the unit has attempted to start a pre- programmed number of times, and has failed to start. The number of cycles and duration are programmable. It is pre-set at 3 cycles with a 10 second duration. This is considered a major fault.

E.Overspeed Shutdown – Indicates the engine is running at an unsafe speed. This is considered a major fault.

F.Engine Running – Indicates that engine is running at a safe operating speed.

DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07) — PAGE 39

Page 39
Image 39
Multiquip operation manual DCA-150SSJU3 Engine Operating Panel, Auto On/Off Engine Controller Mpec

DCA-150SSJU3 specifications

The Multiquip DCA-150SSJU3 is a powerful, reliable diesel generator that is designed to meet the demanding energy needs of various applications, including construction sites, events, and emergency power supply. With its robust construction and advanced technology, the DCA-150SSJU3 stands out in the competitive market of portable generators.

One of the main features of the DCA-150SSJU3 is its impressive output capabilities. This generator generates a continuous output of 150 kVA, which is more than enough to power multiple tools and equipment simultaneously. It is equipped with a high-quality, efficient diesel engine that not only delivers ample power but also ensures fuel efficiency, reducing operational costs over time.

The design of the DCA-150SSJU3 prioritizes user convenience and operational efficiency. It is fitted with a digital control panel that provides real-time monitoring of critical parameters such as voltage, frequency, and operating hours. This user-friendly interface simplifies the process of managing power output and helps operators maintain optimal performance.

Moreover, the DCA-150SSJU3 is equipped with advanced soundproofing technology, making it one of the quieter models in its class. This feature is particularly beneficial in environments where noise regulations must be adhered to, such as residential areas or during nighttime operations.

Durability is another key characteristic of the Multiquip DCA-150SSJU3. The generator is housed in a robust steel enclosure that protects it from external elements, ensuring longevity and reliable performance even in challenging conditions. Additionally, the generator has been designed with easy service access in mind, facilitating maintenance procedures and minimizing downtime.

Safety is paramount in generator design, and the DCA-150SSJU3 does not fall short in this aspect. It is equipped with a comprehensive range of safety features, including low oil shut-off, overload protection, and emergency stop buttons, ensuring safe operation for users.

In conclusion, the Multiquip DCA-150SSJU3 is a versatile and resilient diesel generator that excels in performance, efficiency, and safety. With its powerful output, advanced technologies, and user-friendly design, it is an ideal choice for those needing reliable power solutions across various demanding environments. Whether for temporary applications or as an emergency backup, the DCA-150SSJU3 is a generator that offers peace of mind and dependable performance.