Circuit Breakers

To protect the generator from an overload, a 3-pole, 400 amp, main circuit breaker is provided to protect the U,V, and W OutputTerminals from overload.In addition two single-pole, 20 amp GFCI circuit breakers are provided to protect the GFCI receptacles from overload. Three 50 amp load circuit breakers have also been provided to protect the auxiliary receptacles from overload. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine.

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but DO NOT overfill. Make sure the generator is level. and verify that the oil level is maintained between the two notches (Figure 30) on the dipstick. See Table 9 for proper selection of engine oil.

DCA-150SSJU3 — SETUP

Fuel Check

DANGER - EXPLOSION/FIRE HAZARDS

Fuel spillage on a hot engine can cause a fire or explosion. If fuel spillage occurs, wipe up the spilled fuel completely to prevent fire hazards. NEVER smoke around or near the generator.

Refilling the Fuel System

CAUTION - REFUELINGTHE GENERATOR

ONLY properly trained personel who have read and understand this section should refill the fuel tank system.

Figure 30. Engine Oil Dipstick

When checking the engine oil, be sure to check if the oil is clean. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the John Deere Engine Owner's Manual. Oil should be warm before draining.

Other types of motor oils may be substituted if they meet the following requirements:

API Service Classification CC/SC

API Service Classification CC/SD

API Service Classification CC/SE

API Service Classification CC/SF

This generator has an internal fuel tank located inside the trailer frame and may also be equipped with an environmental fuel tank (Figure 31). ALWAYS fill the fuel tanks with clean fresh #2 diesel fuel. DO NOT fill the fuel tanks beyond their capacities.

Pay attention to the fuel tank capacity when replenishing fuel.The fuel tank cap must be closed tightly after filling. Handle fuel in a safety container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.

Figure 31. Internal Fuel Tank System

PAGE 48 — DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07)

Page 48
Image 48
Multiquip operation manual DCA-150SSJU3 Setup, Circuit Breakers, Lubrication Oil, Fuel Check, Refilling the Fuel System

DCA-150SSJU3 specifications

The Multiquip DCA-150SSJU3 is a powerful, reliable diesel generator that is designed to meet the demanding energy needs of various applications, including construction sites, events, and emergency power supply. With its robust construction and advanced technology, the DCA-150SSJU3 stands out in the competitive market of portable generators.

One of the main features of the DCA-150SSJU3 is its impressive output capabilities. This generator generates a continuous output of 150 kVA, which is more than enough to power multiple tools and equipment simultaneously. It is equipped with a high-quality, efficient diesel engine that not only delivers ample power but also ensures fuel efficiency, reducing operational costs over time.

The design of the DCA-150SSJU3 prioritizes user convenience and operational efficiency. It is fitted with a digital control panel that provides real-time monitoring of critical parameters such as voltage, frequency, and operating hours. This user-friendly interface simplifies the process of managing power output and helps operators maintain optimal performance.

Moreover, the DCA-150SSJU3 is equipped with advanced soundproofing technology, making it one of the quieter models in its class. This feature is particularly beneficial in environments where noise regulations must be adhered to, such as residential areas or during nighttime operations.

Durability is another key characteristic of the Multiquip DCA-150SSJU3. The generator is housed in a robust steel enclosure that protects it from external elements, ensuring longevity and reliable performance even in challenging conditions. Additionally, the generator has been designed with easy service access in mind, facilitating maintenance procedures and minimizing downtime.

Safety is paramount in generator design, and the DCA-150SSJU3 does not fall short in this aspect. It is equipped with a comprehensive range of safety features, including low oil shut-off, overload protection, and emergency stop buttons, ensuring safe operation for users.

In conclusion, the Multiquip DCA-150SSJU3 is a versatile and resilient diesel generator that excels in performance, efficiency, and safety. With its powerful output, advanced technologies, and user-friendly design, it is an ideal choice for those needing reliable power solutions across various demanding environments. Whether for temporary applications or as an emergency backup, the DCA-150SSJU3 is a generator that offers peace of mind and dependable performance.