Power-On

When power is applied, the RTU performs self-diagnostics and the PWR LED is on. The self-diagnostics includes a power-on self-test. During the power-on self-test, all of the LEDs turn on for one second.

Power – green

Alarm – red

Test – yellow

Digital Subscriber Line – green

Ethernet Link – green

PWR ALM TST

DSL

ETHERNET

5620

TM

98-15835

Refer to Troubleshooting, page 14, for LED indications requiring action.

Status LEDs

All of the LEDs turn on and off during the power-on self-test. After a successful self-test, the LEDs should appear as indicated in BOLD in the Condition column below.

LED

Condition

Status

 

 

 

PWR

ON

RTU has power.

 

 

 

ALM

OFF

No active alarms.

 

ON

An alarm condition exists.

 

 

 

TST

OFF

No active tests.

 

ON

The TST LED is on during the power-on self-test and

 

 

during a test initiated by the NSP.

 

 

 

DSL

Blinking

RTU is establishing the active DSL link. The LED blinks

 

 

on and off about five times per second.

 

ON

The DSL link is now active and ready to transmit and

 

 

receive data.

 

OFF

The DSL link has not been established.

 

 

 

ETHERNET

ON

The Ethernet 10BaseT connection to the Ethernet hub or

 

 

PC is active.

 

OFF

No Ethernet 10BaseT device is detected.

 

 

 