BPS-120 User’s Guide

Table 4 BPS-120 Front Panel DC Output LEDs State Definitions

PORT LED

COLOR

DC

DESCRIPTION

INDICATIONS

 

OUTPUT

 

 

 

LED

 

 

 

STATUS

 

DEVICE

Amber

Off

The BPS-120 has detected an external or

FAULT

 

 

internal fault. See Table 5.

 

 

 

 

DEVICE

Red

On

The BPS-120 has detected an external or

FAULT

 

 

internal fault. See Table 5.

 

 

 

 

3 Troubleshooting

Make sure that the BPS-120 is plugged into an appropriate AC power supply.

Table 5 BPS-120 Troubleshooting Tips

PROBLEM

CONDITION

CORRECTIVE ACTION

 

 

 

The STANBY

Faulty or not connected AC

Make sure you are using the

LED is off.

power supply.

correct power line cord and it is

 

plugged into an appropriate

 

 

 

 

100/240 VAC power supply

 

 

receptacle. Check the power line

 

 

fuse.

 

 

Unplug the power line cord and

 

 

plug it in again. Turn the BPS-

 

 

120 on using the rear panel

 

 

switch. If the error persists you

 

 

should contact your vendor or

 

 

Zyxel for servicing.

 

 

 

The STANDBY

The BPS-120 is in standby

Press the STANDBY/ACTIVE

LED is on.

mode.

button to put the BPS-120 into

 

active mode.

 

 

 

 

 

The FAULT LED

The BPS-120 has an internal

Monitor the PWR, TEMP, and

is red.

hardware system fault (PWR,

FAN LEDs, then turn the BPS-

 

TEMP, or FAN LEDs are

120 off or disconnect external

 

red).

devices.

 

 

 

18