VLC Troubleshooting

This chapter covers potential problems and possible remedies. After each problem description, some steps are provided to help you to diagnose and solve the problem.

3.1 The SYS or PWR LED Does Not Turn On

Table 9 SYS LED Troubleshooting

STEPS

CORRECTIVE ACTION

 

 

1Make sure the power wires are properly connected to the power supply and the power supply is operating normally. Make sure you are using the correct power source (refer to the IES User’s Guide for details).

2Make sure the power wires are connected properly.

3Make sure the line card is properly installed.

4The LED itself or the unit may be faulty; contact your vendor.

3.2The ALM LED Is On

The ALM (alarm) LED lights when the line card is overheated or the voltage readings are outside the tolerance levels.

Table 10 ALM LED Troubleshooting

STEPS

CORRECTIVE ACTION

 

 

1Use the sys monitor show command to verify the cause of the alarm. See step 2 if the unit is overheated, and step 3 if the voltages are out of the allowed ranges.

2Ensure that the IES is installed in a well-ventilated area and that normal operation of the fans is not inhibited. Keep the bottom, top and all sides clear of obstructions and away from the exhaust of other equipment.

3If the voltage levels are outside the allowed range, take a screen shot of the sys monitor show command display and contact your vendor.

 

31

VLC1324G User’s Guide