Chapter 3 Troubleshooting
Table 7 ALM LED Troubleshooting
STEPS | CORRECTIVE ACTION |
|
|
2Ensure that the IES is installed in a
3If the voltage levels are outside the allowed range, take a screen shot of the sys monitor status command display and contact your vendor.
3.2Data Transmission
The link is up, but data cannot be transmitted.
Table 8 Data Transmission Troubleshooting
STEPS | CORRECTIVE ACTION |
1 | Check the line card’s port isolation settings. |
| If the subscriber is having problems with video or other |
| sure the line card’s port’s data rates are set high enough. |
|
|
2 | Check the VLAN configuration. |
|
|
3 | Ping the MSC from a computer at the subscriber’s location. |
| If you cannot ping, connect a Ethernet switch to a subscriber slot (that is known to |
| work). |
| If the Ethernet switch works with a different subscriber slot, there may be a problem with |
| the transceiver in the original SFP slot or the configuration for the SFP slot. |
| If using a different slot does not work, try a different Ethernet switch with the original |
| slot. |
|
|
3.3 Local Server
The computer behind an Ethernet switch cannot access a local server connected to the line card.
20 |
|
|
|