4.Insert a UV-rated wire tie (not provided) through the slots at the bottom of the entrance as shown in Figure 8.

844

Figure 14. Inserting the Wire Tie

5.Remove the grommet from the fiber optic drop cable and ground wire entrance.

6.Open the shielding to 1.5 in. beyond the grommet slot where the cable will be coming into the enclosure, per the cable manufacturer’s instructions, exposing 41 in. (104.14 cm) of buffer tube.

7.Open out the shielding to expose the buffer tube, as shown in Figure 15.

1188

Figure 15. Opening Out the Shielding

8.Locate the drop cable clamp on the grounding plate (see Figure 5 on page 35) and remove the Kepnuts, washers, and bar from the posts.

9.Locate the strength member clamp (see Figure 5 on page 35) on the grounding plate and remove the Kepnuts and bar.