Polaris P3000iE manual Air Conditioning Operation, SMART Throttle System

Page 39
Air Conditioning Operation

OPERATION

Safe Operating Precautions

Air Conditioning Operation

For best results, the SMART throttle switch should be in the off position. Bring the generator to a normal operating temperature before applying the air conditioning load. Always allow a 2 minute wait period when manually cycling an air conditioner off and on. A longer wait period may be required under unusually hot weather conditions. Additionally, all other loads should be turned off until the air conditioner has started and is performing normally. It is also important to follow the air conditioner manufacturer's instructions for starting and restarting for proper operation. Some air conditioner manufacturers offer a start capacitor as an extra cost option. The lack of a start capacitor can cause the air conditioner to draw too high a starting current and overload the generator. Contact your air conditioner supplier if you consistently have problems starting your air conditioner with the generator. This generator is not generally recommended for air conditioners exceeding 13,500 BTUs

SMART Throttle System

With the SMART throttle switch in the ON position, engine speed is automatically lowered when loads are reduced, turned off, or disconnected. When devices are turned on or connected, the engine returns to the proper speed to power the electrical load. When the smart throttle is in the OFF position, the engine runs at rated load RPM.

Appliances with large start-up power demands may not allow the engine to reach normal operating RPM when they are connected to the generator. Position the SMART throttle switch to OFF and connect the device to the generator. If the engine still will not reach normal operating speed, ensure the device does not exceed the rated load capacity of the generator.

If high electrical loads are simultaneously connected, position the SMART throttle switch to OFF to reduce voltage changes.

The SMART throttle system is not effective for use with devices or appliances requiring only momentary power. If the device or appliance will be quickly turned on and off, the SMART throttle switch should be in the OFF position. When using the DC output, position the SMART throttle switch to OFF.

38

Image 39
Contents POLARIS POWER P3000iE Operator’s Manual Australian modelDEATH TABLE OF CONTENTS Welcome INTRODUCTIONIntended Use Safety PrecautionsSignal Words and Safety Terms Warnings, Cautions and NoticesALCOHOL OR DRUG USE Serial Number Identification Numbers and LocationsSAFETY Safety Warnings and PrecautionsGeneral Before and During Operation Do not refuel while engine is running Operator Safety Fuel Safety Carbon Monoxide Safety Fire Safety Electrical SafetyEquipment Modifications Extension Cord InformationHot Exhaust Caution Carbon Monoxide WarningOutdoor Use ONLY Danger Label DANGERSAFETY DESCRIPTION CONTROLS AND FEATURESGenerator Components NOMENCLATUREGround Terminal Output Indicator Indicator PanelLow Oil Indicator Overload IndicatorSMART Throttle Switch Ignition SwitchFuel Valve Lever AC Receptacles DC Receptacle and FuseFuel Volume Indicator Ground TerminalStarter Recoil Grip Adding Engine Oil FIRST USE INSTRUCTIONSFuel Recommendation Adding Fuel Wheel Kit Installation Wheel assemblyLocking swivel wheel Fuel Level PRE-OPERATIONINSPECTIONEngine Oil Fuel LineRefueling OPERATIONSafe Operating Precautions Fuel Recommendations1.Remove the fuel tank cap A Starting the Engine Before Starting the Engine6. To start the generator using the ignition Stopping the Engine AC Operation AC Capacity DEVICE Wattage Reference TableRUNNING ADDITIONALPower Management Connecting the Battery Charging Cable includedDC Operation Connecting the Battery Charging Cable Disconnecting the Battery Charging Cable SMART Throttle System Air Conditioning OperationSystem Requirements Standby PowerConnections to a Building Electrical System System GroundCarburetor Modification High Altitude UseEmission Control System Information Source of EmissionsAlterations Replacement Parts Problems Affecting EmissionsImportance of Maintenance MAINTENANCESafety Precautions Maintenance SafetyPeriodic Maintenance Chart Periodic MaintenanceOpening the Service Door Fuel Line Inspection Fuel SystemFuel Tank Strainer Engine Oil Oil RecommendationOil Level Inspection Oil Change 7.Re-installthe oil drain bolt B Air Filter Inspection Air FiltersSpark Plug Spark Plug Inspection and Replacement8.Using a wire-typefeeler gauge Battery Cleaning BatteryBattery Safety Accessing the BatteryVOLTAGE Battery Charging Sealed OnlyCHARGE TIME STATE OFSpark Arrestor Spark Arrestor MaintenanceTRANSPORTATION AND STORAGE TransportationTransporting the Generator Storage Preparation StorageAccessing the Fuel Tank Draining Fuel from the Fuel Tank and Carburetor Fogging the Engine Removing from Storage Battery StorageStorage Precautions Generator ExerciseALTERNATOR SPECIFICATIONSPOLARIS Power Generator P3000iEGREASE / SPECIALIZED LUBRICANTS P3000iE POLARIS Power GeneratorGENERATOR ENGINE OILInverter Module DIAGRAMWIRINGEngine Turns Over, but Will Not Start TROUBLESHOOTINGSOLUTION Engine Will Not Turn OverEngine Backfires Engine Lacks PowerEngine Runs Irregularly, Stalls, or Misfires Engine Pings or KnocksPOSSIBLE RICH No Power at DC ReceptaclePOSSIBLE LEAN FUEL CAUSEEngine Stops or Loses Power No Power at AC ReceptaclesPOLARIS POWER GENERATOR WARRANTY WARRANTYABOUT THIS WARRANTY DOCUMENT WARRANTY REGISTRATION FORMWarranty Period for consumer use 3 years WARRANTY PERIODTRANSFER OF WARRANTY Warranty repairsWARRANTY EXCLUSIONS POLARIS POWER GENERATOR OWNER RESPONSIBILITY IMPORTANT NOTICE COMMENTS MAINTENANCE LOGSERVICE DATE/HOURSINDEX INDEX
Related manuals
Manual 1 pages 40.65 Kb Manual 1 pages 41.73 Kb

P3000iE specifications

The Polaris P3000iE is a robust and innovative inverter generator designed to deliver reliable power for various applications, whether for outdoor adventures or emergency backup. Renowned for its portability and efficiency, the P3000iE is an excellent choice for users who require a balance between power output and convenience.

One of the standout features of the Polaris P3000iE is its impressive 3000-watt output, which makes it suitable for powering a wide range of devices. From camping equipment such as portable refrigerators and lighting systems to tools and household appliances during power outages, the P3000iE meets diverse energy needs with ease. This generator is equipped with a powerful and fuel-efficient engine that ensures an extended runtime, often exceeding 10 hours on a single tank of gas.

The generator incorporates advanced inverter technology, enabling it to produce clean and stable power free from voltage spikes and surges. This makes it ideal for sensitive electronics, including laptops, smartphones, and entertainment systems, ensuring their safety during operation. The P3000iE's quiet operation, typically rated at only 58 decibels, allows users to enjoy a peaceful environment, a critical feature for camping trips or during night-time use.

Portability is another defining characteristic of the Polaris P3000iE. Weighing just over 60 pounds, it features a compact design with integrated wheels and a telescoping handle for easy transportation. The generator is user-friendly, equipped with a digital display that provides real-time information on power output, fuel level, and operational status, enhancing the overall user experience.

Furthermore, the P3000iE is designed with several safety features, including overload protection and low oil shutdown, ensuring that the generator operates securely and prolonging its lifespan. It also comes with multiple outlets, including standard 120V receptacles and USB ports, allowing for versatile connectivity options.

In summary, the Polaris P3000iE stands out as a high-performance inverter generator that excels in providing reliable, clean, and quiet power. With its advanced technologies, portable design, and user-friendly features, it caters to the needs of outdoor enthusiasts, homeowners, and professionals alike, making it a valuable addition to any power solution toolkit.