Porter-Cable PH350IS Grounding the Generator, Obtaining Electricity from the Generator

Page 11

GROUNDING THE GENERATOR

A grounding lug is supplied with the generator for use when required by local electrical ordinances. Refer to article 250 of the National Electrical Code to clarify any needed grounding information. Your local electric company or a certified electrician should be able to help you with this information.

NOTE: Your engine is already grounded to the frame by a grounding strap.

Grounding Lug

OBTAINING ELECTRICITY FROM THE GENERATOR

There are basically 2 ways to obtain electricity from a generator:

1.Use of extension cords directly from the generator to the appliance, lights, tools, etc.

2.Use of a double-throw transfer switch installed directly to the main electrical supply outside of house.

EXTENSION CORDS

When using an appliance or tool at a considerable distance from the generator, a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that accepts the tool's plug MUST be used in order to reduce the risk of electrical shock. A cord of adequate size must be used. Using the following chart to determine the minimum wire size required.

Extension Cord Wire Gauge Chart

Cord

Wire Gauge

 

Length

Size

Amperage

0 to 100 ft.

12 ga.

*Up to 20 amp draw

 

 

 

0 to 100 ft.

10 ga.

Up to 30 amp draw

*NOTE: When amperage exceeds 20 amp; a 12 gauge extension cord should not be used for long distances.

An extension cord that is hot to the touch is overloaded.

Repair or replace damaged extension cords immediately.

DOUBLE THROW TRANSFER SWITCH

Potential hazards exist when a portable electric generator is connected to the main electrical supply coming into the house.

It is at that point that the electrical generator could feed back into the utility company's system causing possible electrocution of workers who are repairing the electrical lines.

To avoid back feeding of electricity into utility systems, a double-throw transfer switch must be installed between the generator and utility power. The Double- Throw Transfer Switch should be installed by a licensed electrician and in com- pliance with all state and local electrical codes. (When installing a Double-

Throw Transfer Switch, a minimum of 10 gauge wiring must be used.)

The electrician should also install a sub-panel to isolate the circuits you would want to use during an emergency or electrical power outage. Your generator will not be large enough to handle the load of all the lights, appliances, TV, etc. at one time. To select which items to run during the electrical power outage, see Wattage Calculation section in this manual.

11- ENG

D27381

Image 11
Contents Generator Consumer Safety Information Consumer General and Service InformationRisk of Electrocution and Fire Safety Guidelines / DefinitionsImportant Safety Instructions When installing a DoubleGenerator in rain When damagedRisk of Electrocution and Fire OperationConfined Area Risk of FireUnit Indoors or in ANY Risk of Unsafe Operation Risk of Breathing Inhalation HazardRisk of HOT Surfaces Risk from Lifting SpecificationsRisk of Moving Parts Extension Cord Wrap Forms and Protective BAR AssemblyRemove Generator from Carton Other Loose PartsHandle Rubber BumperExtension Cords Double Throw Transfer SwitchGrounding the Generator Obtaining Electricity from the GeneratorOperation To Start the Engine Stopping Engine Connecting Electrical LoadsCustomer Responsibilities Table MaintenanceEngine Maintenance Generator MaintenanceGenerator StorageEngine Preparation Determining Wattage Requirements Wattage CalculationsStarting Wattage Requirements Application GuideAppliance or Load Device Typical Device Wattage Total Household Wattage CalculatorStart Troubleshooting GuideResponsibility of Original Purchaser initial User Limited WarrantyQuick Facts