WARNING: Alternative fuels (not gas- oline) such as
HOW TO STOP YOUR UNIT
SRelease the throttle trigger.
S Push and release the engine ON/STOP switch. The switch will automatically return to the ON position. Wait 5 seconds before at- tempting to restart unit to allow switch to reset.
ON/STOP Switch
HOW TO START YOUR UNIT
WARNING: Avoid any contact with the muffler. A hot muffler can cause serious burns.
Starting Position
HELPFUL TIP
If your engine still does not start after following these instructions, please call
STARTING A COLD ENGINE (or a warm engine after running out of fuel)
NOTE: DO NOT squeeze the throttle trigger until the engine has started and runs.
Primer Bulb | Starter Handle |
ThrottleMuffler
Trigger Start
Lever
1.Set unit on a flat surface.
2.Slowly press the primer bulb 6 times.
3.Move the start lever to the START position.
4.Pull starter rope handle sharply until en- gine starts and runs.
5.Allow unit to run for
STARTING A WARM ENGINE
Pull starter rope sharply until engine starts and runs.
NOTE: Normally, the warm starting procedure can be used within 5
STARTING A FLOODED ENGINE
Move the start lever to the RUN position and fully squeeze throttle trigger. Pull the starter handle repeatedly while squeezing throttle trigger until engine starts and runs. This could require pulling the starter handle many times, depending on how badly the unit is flooded. If the unit still doesn’t start, refer to TROUBLE- SHOOTING TABLE or call
OPERATING THE COUPLER
This model is equipped with a coupler which enables optional attachments to be installed. The optional attachments are:
MODEL:
Edger . . . . . . . . . . . . . . . . . . . . . PP1000E Cultivator . . . . . . . . . . . . . . . . . . PP2000T Blower . . . . . . . . . . . . . . . . . . . . PP3000B Pruner . . . . . . . . . . . . . . . . . . . . PP5000P Pruner . . . . . . . . . . . . . . . . . . . . PP5500P
WARNING: Always stop unit and dis- connect spark plug before removing or instal- ling attachments.
REMOVING TRIMMER ATTACH- MENT (OR OTHER OPTIONAL ATTACHMENTS)
CAUTION: When removing or installing at- tachments, place the unit on a flat surface for stability.
1.Loosen the coupler by turning the knob counterclockwise.
Coupler
AttachmentLOOSEN
Knob
TIGHTEN
2.Press and hold the locking/release button.
Locking/Release
Button
Attachment | Coupler | Upper Shaft |
11