Omega CNI32, CNI8 Enter Communication Option Menu, Communication Parameters Submenu, Baud Submenu

Page 54

ENTER COMMUNICATION OPTION MENU:

Press a 1) Press a, if necessary, until CNFG prompt appears. Press d 2) Display advances to INPT Input Menu.

Press a 3) Press a, if necessary, until Display advances to COMM Communication Options Menu.

Press d 4) Display advances to C.PAR Communication Parameters Submenu.

If Communication Option is not installed, the display shows NONE and skips to the Color Display Menu.

COMMUNICATION PARAMETERS SUBMENU:

Allows the user to adjust Serial Communications Settings of the instrument. When connecting an instrument to a computer or other device, the Communications Parameters must match. Generally the default settings (as shown in Section 5) should be utilized.

Press d 5) Display advances to BAUD Baud Submenu.

BAUD SUBMENU:

Press

d

6) Display flashes previous selection for BAUD value.

Press

b

7) Scroll through the available selections: 300_, 600_, 1200,

 

 

2400, 4800, 9600, 19.2K.

Press d

8) Display shows STRD stored message momentarily and then

 

 

advances to PRTY only, if it was changed, otherwise press a to

 

 

advance to PRTY Parity Submenu.

PARITY SUBMENU:

Press

d

9) Display flashes previous selection for “Parity”.

Press

b

10) Scroll through the available selections: NO, ODD, EVEN.

Press d

11) Display shows STRD stored message momentarily and then

 

 

advances to DATA only, if it was changed, otherwise press a to

 

 

advance to DATA Data Bit Submenu.

DATA BIT SUBMENU:

Press d 12) Display flashes previous selection for “Data Bit”. Press b 13) Scroll through the available selections: 7-BIT, 8-BIT.

Press d 14) Display shows STRD stored message and then advances to STOP only, if it was changed, otherwise press a to advance to STOP Stop Bit Submenu.

50

Image 54
Contents User’s Guide Servicing North America Table of Contents List of Figures List of TablesTIP Part Introduction DescriptionSafety Considerations EMC ConsiderationsBefore You Begin Part Setup Front PanelInput PowerRear Panel Connections OptionElectrical Installation Power Connections Main Power Connections Fuse Requirement see specificationsThermocouple Wiring Hookup TC Wire Color Chart Thermocouple3 Two/Three/Four-Wire RTD Ohm Wiring HookupProcess Current Process VoltageWithout Sensor Excitation Wiring Outputs Use copper conductorsRS-232 Output Wiring Hookup b RS-485 Output Wiring Hookup Snubber Circuits Wiring HookupDual Display Color Setup 8DH Dual Horizontal 8DV Dual VerticalUse a jumper for Green or RED, never leave S1 open Part Operation Configuration Mode IntroductionButton Function in Configuration Mode Turning your Controller On for the First TimeMenu Configuration Flow Chart for ID and SetpointsEntering Your NON-DEFAULT Full Security ID Number Entering Your NON-DEFAULT SETPOINT/ID Security ID NumberID Number Set Points SetpointConfiguration Menu Enter Configuration MenuInput Type Menu Thermocouple Submenu Input Type ThermocoupleEnter Input Type Menu Thermocouple TypesRTD Types Input Type RTDRTD Submenu RTD Value SubmenuProcess Submenu Reading ConfigurationInput Type Process Process TypesDecimal Point Submenu Enter Reading Configuration MenuTemperature Unit Submenu Filter Constant SubmenuReading Configuration If Process was selected INPUT/READING Scale and Offset SubmenuConversion Table Range Conversion NumberAlarm Enter Alarm 1 MenuAlarm 1 ENABLE/DISABLE Submenu Alarm 1 ABSOLUTE/DEVIATION SubmenuAlarm 1 LATCH/UNLATCH Submenu Contact Closure Submenu Active SubmenuAlarm ENABLE/DISABLE AT Power on Alarm 1 LOW Value SubmenuAlarm 1 HI Value Submenu Analog Output Retransmission Enter Analog Output MenuReading Analog Output ENABLE/DISABLE SubmenuCURRENT/VOLTAGE Submenu OUTFor example Enter Alarm 2 Menu Alarm 2 ENABLE/DISABLE SubmenuLoop Break Time/Field Calibration Loop Break ENABLE/DISABLE SubmenuReading Adjust Submenu Enter Loop Break Time MenuSetpoint Deviation ENABLE/DISABLE Submenu Thermocouple Field Calibration SubmenuFlow Chart for Output OutputEnter Output 1 Menu Self SubmenuMINIMUM/PERCENT LOW Submenu MAXIMUM/PERCENT High Submenu Control Type OutputAction Type Submenu Auto PID SubmenuAnti Integral Submenu Start Auto Tune PID Proportional Band SubmenuReset Setup Submenu Rate Setup SubmenuCycle Time Submenu Damping Factor Submenu Deadband SubmenuEnter Output 2 Menu Control Type SubmenuAction Type Submenu Cycle Time Submenu Ramp ENABLE/DISABLE Submenu Ramp & SoakEnter Ramp and Soak Menu Soak ENABLE/DISABLE Submenu Ramp Value SubmenuSoak Value Submenu Entering or Changing Your NON-DEFAULT ID Code ID CodeEnter ID Code Menu Entering or Changing Your Default ID Code Full Security Level SubmenuSETPOINT/ID Security Level Submenu 13 Flow Chart for Communication Option Communication OptionBaud Submenu Enter Communication Option MenuCommunication Parameters Submenu Parity SubmenuModbus Protocol Submenu Stop BIT SubmenuBUS Format Submenu Line Feed SubmenuData Flow Mode Submenu Communication Interface Standard SubmenuData Separation Character Submenu Main Reading Submenu Alarm Status SubmenuData Format Submenu Peak Value SubmenuTransmit Time Interval Submenu Address Setup SubmenuAddress Value Submenu Transmit Time Interval Value SubmenuEnter Display Color Selection Menu Alarm 1 Display Color SubmenuDisplay Color Selection Normal Color Display SubmenuDisplay Colors change sequences Alarm 2 Display Color SubmenuExample Green RED AmberRED Green Cmrr Part SpecificationsNmrr ControlControl Output 1 SSRExcitation InsulationGeneral Input Properties Input Type Range AccuracyPart Factory Preset Values Factory preset valueMenu Items Factory Preset Values Notes Part CE Approvals Information Measurement CategoryPage Page WARRANTY/DISCLAIMER Return REQUESTS/INQUIRIESFLOW/LEVEL TemperaturePRESSURE, Strain and Force Data Acquisition

CNI16, CNI32, CNI8DH, CNI8C, CNI16D specifications

The Omega CNI series, including models CNI8DV, CNI8, CNI8DH, CNI32, and CNI16, represents a cutting-edge line of sensors designed for various industrial applications. Known for their reliability and versatile functionality, these sensors play a crucial role in monitoring and controlling multiple parameters in different environments.

The CNI8DV model is equipped with dual voltage outputs, enabling flexibility in integration with various systems. This feature allows users to choose between standard and high voltage operating conditions, making it suitable for a wide range of applications. Its high precision and quick response times deliver accurate measurements, essential for critical processes where timing and accuracy are paramount.

The CNI8 model offers robust performance with an extensive measurement range. This model is particularly noteworthy for its advanced signal processing technology, which improves measurement stability and accuracy. It utilizes digital filtering and calibration techniques to enhance performance and ensure consistent output, minimizing the effects of environmental fluctuations.

In the CNI8DH variant, enhanced durability is a key characteristic. This model features a more robust housing that protects it from harsh environmental conditions. It is designed to withstand high humidity, dust, and varying temperatures, making it suitable for outdoor applications or environments where exposure to elements is a concern. It also includes real-time diagnostics to monitor its operational health, allowing for proactive maintenance.

The CNI32 model stands out with its higher measurement capacity and greater flexibility in configurations. This sensor can handle multiple input types, including temperature, pressure, and flow rates. Its modular design allows users to customize it for specific applications, making it ideal for industries ranging from manufacturing to energy production.

The CNI16 model is designed for standard applications requiring precision and reliability. Its compact size allows for easy installation in tight spaces, while still delivering high performance. Enhanced connectivity options support integration with various data acquisition systems and industrial networks, enabling seamless data collection and monitoring.

In summary, the Omega CNI series exemplifies state-of-the-art sensor technology, offering a range of features that cater to diverse industrial needs. From versatile voltage outputs in the CNI8DV to the rugged design of the CNI8DH, each model is engineered to provide accurate, reliable readings with the ability to withstand challenging conditions. Whether for monitoring environmental conditions or precise measurements in manufacturing processes, the CNI series continues to be a top choice for professionals seeking high-quality sensors.