Omega CNI8DH, CNI8DV manual Alarm 2 Display Color Submenu, Example, Display Colors change sequences

Page 60

ALARM 2 DISPLAY COLOR SUBMENU:

Press d 11) Display flashes previous selection for “Alarm 2 Color Display”. Press b 12) Scroll through the available selections: GRN, RED or AMBR. Press d 13) Display shows STRD stored message momentarily and then

momentarily shows the software version number, followed by RST Reset, and then proceeds to the Run Mode.

IN ORDER TO DISPLAY ONE COLOR, SET THE SAME DISPLAY COLOR ON ALL THREE SUBMENUS ABOVE.

If user wants the Display to change color every time when both Alarm 1 and Alarm 2 are triggered, the Alarm values should be set in such a way that Alarm 1 value is always on the top of Alarm 2 value, otherwise value of Alarm 1 will overwrite value of Alarm 2 and Display Color would not change when Alarm 2 is triggered.

Example 1:

Output 1 & Output 2 = SSR

Alarm Setup: Absolute, Above, Alarm 2 HI Value “ALR.H” = 200, Alarm 1 HI Value “ALR.H” = 400

"Color Display" Setup: Normal Color “N.CLR” = Green, Alarm 1 Color “1.CLR” = Amber, Alarm 2 Color “2.CLR” = Red

Display Colors change sequences:

GREEN

RED

AMBER

•--

------------------------------•-----------------------------

•------------------------------

0

AL2.H = 200

AL1.H = 400

 

 

Example 2:

 

 

 

Output 1 & Output 2 = Pulse

 

 

Alarm Setup: Absolute, Below, Alarm 2 Low Value “ALR.L” = 300, Alarm 1 Low Value “ALR.L” = 100

Color Display Setup: "N.CLR" = Green, "1.CLR" = Amber, "2.CLR" = Red

Display Colors change sequences:

AMBER

RED

GREEN

--------------

•----------------------------------

•-------------------------------------------

--•

0

 

AL1.L = 100

AL2.L = 300

 

56

Image 60
Contents User’s Guide Servicing North America Table of Contents List of Figures List of TablesTIP Part Introduction DescriptionSafety Considerations EMC ConsiderationsBefore You Begin Part Setup Front PanelPower Rear Panel ConnectionsInput OptionElectrical Installation Power Connections Main Power Connections Fuse Requirement see specificationsThermocouple Wiring Hookup TC Wire Color Chart Thermocouple3 Two/Three/Four-Wire RTD Ohm Wiring HookupProcess Current Process VoltageWithout Sensor Excitation Wiring Outputs Use copper conductorsRS-232 Output Wiring Hookup b RS-485 Output Wiring Hookup Snubber Circuits Wiring HookupDual Display Color Setup 8DH Dual Horizontal 8DV Dual VerticalUse a jumper for Green or RED, never leave S1 open Operation Configuration Mode Introduction Button Function in Configuration ModePart Turning your Controller On for the First TimeMenu Configuration Flow Chart for ID and SetpointsEntering Your NON-DEFAULT Full Security ID Number Entering Your NON-DEFAULT SETPOINT/ID Security ID NumberID Number Set Points SetpointConfiguration Menu Enter Configuration MenuInput Type Menu Input Type Thermocouple Enter Input Type MenuThermocouple Submenu Thermocouple TypesInput Type RTD RTD SubmenuRTD Types RTD Value SubmenuReading Configuration Input Type ProcessProcess Submenu Process TypesEnter Reading Configuration Menu Temperature Unit SubmenuDecimal Point Submenu Filter Constant SubmenuReading Configuration If Process was selected INPUT/READING Scale and Offset SubmenuConversion Table Range Conversion NumberAlarm Enter Alarm 1 MenuAlarm 1 ENABLE/DISABLE Submenu Alarm 1 ABSOLUTE/DEVIATION SubmenuAlarm 1 LATCH/UNLATCH Submenu Contact Closure Submenu Active SubmenuAlarm ENABLE/DISABLE AT Power on Alarm 1 LOW Value SubmenuAlarm 1 HI Value Submenu Analog Output Retransmission Enter Analog Output MenuAnalog Output ENABLE/DISABLE Submenu CURRENT/VOLTAGE SubmenuReading OUTFor example Enter Alarm 2 Menu Alarm 2 ENABLE/DISABLE SubmenuLoop Break ENABLE/DISABLE Submenu Reading Adjust SubmenuLoop Break Time/Field Calibration Enter Loop Break Time MenuSetpoint Deviation ENABLE/DISABLE Submenu Thermocouple Field Calibration SubmenuFlow Chart for Output OutputEnter Output 1 Menu Self SubmenuMINIMUM/PERCENT LOW Submenu MAXIMUM/PERCENT High Submenu Control Type OutputAction Type Submenu Auto PID SubmenuAnti Integral Submenu Start Auto Tune PID Proportional Band SubmenuReset Setup Submenu Rate Setup SubmenuCycle Time Submenu Damping Factor Submenu Deadband SubmenuEnter Output 2 Menu Control Type SubmenuAction Type Submenu Cycle Time Submenu Ramp ENABLE/DISABLE Submenu Ramp & SoakEnter Ramp and Soak Menu Soak ENABLE/DISABLE Submenu Ramp Value SubmenuSoak Value Submenu Entering or Changing Your NON-DEFAULT ID Code ID CodeEnter ID Code Menu Entering or Changing Your Default ID Code Full Security Level SubmenuSETPOINT/ID Security Level Submenu 13 Flow Chart for Communication Option Communication OptionEnter Communication Option Menu Communication Parameters SubmenuBaud Submenu Parity SubmenuStop BIT Submenu BUS Format SubmenuModbus Protocol Submenu Line Feed SubmenuData Flow Mode Submenu Communication Interface Standard SubmenuData Separation Character Submenu Alarm Status Submenu Data Format SubmenuMain Reading Submenu Peak Value SubmenuAddress Setup Submenu Address Value SubmenuTransmit Time Interval Submenu Transmit Time Interval Value SubmenuAlarm 1 Display Color Submenu Display Color SelectionEnter Display Color Selection Menu Normal Color Display SubmenuAlarm 2 Display Color Submenu ExampleDisplay Colors change sequences Green RED AmberRED Green Part Specifications NmrrCmrr ControlControl Output 1 SSRExcitation InsulationGeneral Input Properties Input Type Range AccuracyPart Factory Preset Values Factory preset valueMenu Items Factory Preset Values Notes Part CE Approvals Information Measurement CategoryPage Page WARRANTY/DISCLAIMER Return REQUESTS/INQUIRIESTemperature PRESSURE, Strain and ForceFLOW/LEVEL Data Acquisition

CNI16, CNI32, CNI8DH, CNI8C, CNI16D specifications

The Omega CNI series, including models CNI8DV, CNI8, CNI8DH, CNI32, and CNI16, represents a cutting-edge line of sensors designed for various industrial applications. Known for their reliability and versatile functionality, these sensors play a crucial role in monitoring and controlling multiple parameters in different environments.

The CNI8DV model is equipped with dual voltage outputs, enabling flexibility in integration with various systems. This feature allows users to choose between standard and high voltage operating conditions, making it suitable for a wide range of applications. Its high precision and quick response times deliver accurate measurements, essential for critical processes where timing and accuracy are paramount.

The CNI8 model offers robust performance with an extensive measurement range. This model is particularly noteworthy for its advanced signal processing technology, which improves measurement stability and accuracy. It utilizes digital filtering and calibration techniques to enhance performance and ensure consistent output, minimizing the effects of environmental fluctuations.

In the CNI8DH variant, enhanced durability is a key characteristic. This model features a more robust housing that protects it from harsh environmental conditions. It is designed to withstand high humidity, dust, and varying temperatures, making it suitable for outdoor applications or environments where exposure to elements is a concern. It also includes real-time diagnostics to monitor its operational health, allowing for proactive maintenance.

The CNI32 model stands out with its higher measurement capacity and greater flexibility in configurations. This sensor can handle multiple input types, including temperature, pressure, and flow rates. Its modular design allows users to customize it for specific applications, making it ideal for industries ranging from manufacturing to energy production.

The CNI16 model is designed for standard applications requiring precision and reliability. Its compact size allows for easy installation in tight spaces, while still delivering high performance. Enhanced connectivity options support integration with various data acquisition systems and industrial networks, enabling seamless data collection and monitoring.

In summary, the Omega CNI series exemplifies state-of-the-art sensor technology, offering a range of features that cater to diverse industrial needs. From versatile voltage outputs in the CNI8DV to the rugged design of the CNI8DH, each model is engineered to provide accurate, reliable readings with the ability to withstand challenging conditions. Whether for monitoring environmental conditions or precise measurements in manufacturing processes, the CNI series continues to be a top choice for professionals seeking high-quality sensors.