Roberts Gorden HE-80, HE-60, HE-175 Motor and Blower Assembly Blower Inlet Gasket Door Switch

Page 64

HE-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

 

Motor and Blower Assembly

Blower Inlet Gasket

 

 

Door Switch

Burner Cup

 

 

Assembly

 

 

Mica Window

Orifice

 

 

 

Assembly

 

Air Adapter Collar

 

 

Hot Surface

 

Gas Valve

 

 

Igniter

 

 

 

 

Pressure Switch

 

 

Gas Valve

Flame Sensor

 

 

Tube Gasket

 

 

Burner Side

 

Blower Side

Transformer

Air Pressure Tap

Air Pressure Tap

 

 

58

Image 64
Contents Vantage Page Roberts-Gordon LLC Page Table of Figures Page Heater Safety Manpower RequirementsSafety Labels and Their Placement California PropositionTop and Bottom Panel Label Placement Side and Back Panel Label Placement Installer Responsibility Wall TagNational Standards and Applicable Codes Page Standard Reflector Inches CentimetersInches ModelC D Unapproved TUBE, Opposite 45 Reflector Venting National Standards and Applicable Codes Major Components Standard Parts List Contents of Heater Burner CartonComponent Package Guide Heater Installation Typical Suspension Details Critical Hanger Placement Outdoor Installation Outdoor MountingStainless steel reflector packages Linear Heater Layout Overview Burner Tube Installation Tube Clamp Package InstallationCoupling and Tube Assembly 1 Coupling and Tube Assembly2 Coupling and Tube Assembly Turbulator InstallationHanger Burner Tube Reflector 1 Reflector, U-Clip and Reflector Support Installation Description Part Number Reflector Support PackageBurner Installation Optional Heater Accessories Tube, Standard Tube heater Layout Overview 2 Elbow Installation Elbow Package Configuration .2.1 Elbow Installation3 Reflector Joint Installation 4 Reflector Joint Installation 5 Reflector Joint Detail Reflector Joint Detail2 Side Reflector Installation Scr ews 2 Frame Shield Installation Distance a Extension2 Grille End Cap Installation 3 Grille InstallationOutdoor Vent Cap Installation United States Requirements Canadian RequirementsUnvented Operation Horizontal VentingVenting Options Horizontal Ventilation 4 10 cm Pipe Vertical Ventilation 4 10 cm PipeCommon Sidewall Venting TOP ViewCommon Vertical Venting Outside Combustion Air SupplyVertical Outside Air Supply for Single Heater Installation Horizontal Outside Air Supply for Single Heater InstallationVertical Outside Air Supply for Double Heater Installation Horizontal Outside Air Supply for Double Heater InstallationGAS Piping Incorrect Positions Wrong Installation Correct PositionsLine Voltage Thermostat Wiring WiringLow Voltage Thermostat with One Burner Page Internal Wiring For External Thermostat ConnectionLadder Diagram Operation and Maintenance Pre-Season Maintenance and Annual InspectionSequence of Operation To Shut Off HeaterInstallation Code and Annual Inspections Maintenance Checklist Vicinity of the HeaterVehicles and Other ObjectsSafety Labels Reflector Support StrapsTubes Gas LineTroubleshooting Honeywell SmartValve II Troubleshooting LED Status IndicatesTroubleshooting Flow Chart Yes Manifold Gas Pressure Setting Natural Gas LP GasReplacement Parts Motor and Blower Assembly Blower Inlet Gasket Door Switch Description Part Number General Specifications DimensionsGAS Pressure AT Manifold Pipe ConnectionROBERTS-GORDON LLC will not PAY for Warranty is Void ifLimitations on Authority Representatives Page Page Page
Related manuals
Manual 2 pages 4.23 Kb

HE-125, HE-150, HE-100, HE-40, HE-175 specifications

Roberts Gordon is renowned for its innovative heating solutions, and among its standout offerings are the HE-125, HE-175, HE-100, HE-150, and HE-40 heaters. These products exemplify cutting-edge technology and efficiency designed for commercial and industrial applications.

The HE-125 and HE-175 variants are among the top-rated infrared heaters available. They utilize advanced infrared technology to provide direct heating to objects, reducing the need to heat the entire ambient air volume. This method results in energy savings while delivering consistent warmth where it's needed most. The HE-125 model has a heating capacity of 125,000 BTU, while the HE-175 pushes this to 175,000 BTU, making them suitable for larger spaces like warehouses and manufacturing facilities.

The HE-100 and HE-150 heaters are designed for flexibility and efficiency in a range of operational environments. These models support a wide range of input fuels including natural gas and propane, making them an adaptable choice for various setups. The HE-100 has an output of 100,000 BTU, and the HE-150 follows with 150,000 BTU. Both units are engineered with robust construction materials, ensuring durability and longevity, while also featuring advanced safety systems to prevent overheating and other hazards.

In contrast, the HE-40 heater stands out for smaller spaces, making it an ideal option for garages, workshops, or smaller commercial environments. With a capacity of 40,000 BTU, it effectively delivers consistent warmth without the excessive energy consumption associated with larger units.

All Roberts Gordon models prioritize energy efficiency, often meeting or exceeding current energy codes. They incorporate advanced control systems that allow precise temperature regulation, further optimizing energy use. Additionally, the heaters are designed with minimal maintenance needs, featuring durable components that ensure long-term reliability and performance.

With a legacy of quality and innovation, Roberts Gordon continues to set the standard in infrared heating technology. The HE series exemplifies a commitment to efficiency, safety, and versatility, making them suitable for a wide range of commercial and industrial applications. Whether heating a vast warehouse or a small workshop, these heaters provide reliable performance tailored to user needs.