Roberts Gorden HE-175, HE-60, HE-80, HE-40, HE-100, HE-150, HE-125 Side and Back Panel Label Placement

Page 9

SECTION 1: HEATER SAFETY

FIGURE 2: Side and Back Panel Label Placement

Control Side Panel

Control Side Panel (Inside)

Clearances to Combustibles Label

Wiring Label

Vent Length Label

Back Panel

Lighting Instruction Plate Label

Description

Part Number

Clearances to Combustibles Label

91013415

 

 

Wiring Label

91013300

 

 

Vent Length Label

91039500

 

 

Lighting Instruction Plate Label

91029602

 

 

3

Image 9
Contents Vantage Page Roberts-Gordon LLC Page Table of Figures Page Manpower Requirements Heater SafetySafety Labels and Their Placement California PropositionTop and Bottom Panel Label Placement Side and Back Panel Label Placement Wall Tag Installer ResponsibilityNational Standards and Applicable Codes Page Inches Centimeters Standard ReflectorModel InchesC D Unapproved TUBE, Opposite 45 Reflector Venting National Standards and Applicable Codes Major Components Contents of Heater Burner Carton Standard Parts ListComponent Package Guide Heater Installation Typical Suspension Details Outdoor Mounting Critical Hanger Placement Outdoor InstallationStainless steel reflector packages Linear Heater Layout Overview Tube Clamp Package Installation Burner Tube Installation1 Coupling and Tube Assembly Coupling and Tube AssemblyTurbulator Installation 2 Coupling and Tube AssemblyHanger Burner Tube Reflector Description Part Number Reflector Support Package 1 Reflector, U-Clip and Reflector Support InstallationBurner Installation Optional Heater Accessories Tube, Standard Tube heater Layout Overview Elbow Package Configuration .2.1 Elbow Installation 2 Elbow Installation3 Reflector Joint Installation Reflector Joint Detail 4 Reflector Joint Installation 5 Reflector Joint Detail2 Side Reflector Installation Scr ews Distance a Extension 2 Frame Shield Installation3 Grille Installation 2 Grille End Cap InstallationOutdoor Vent Cap Installation Canadian Requirements United States RequirementsUnvented Operation Horizontal VentingVenting Options Vertical Ventilation 4 10 cm Pipe Horizontal Ventilation 4 10 cm PipeTOP View Common Sidewall VentingOutside Combustion Air Supply Common Vertical VentingHorizontal Outside Air Supply for Single Heater Installation Vertical Outside Air Supply for Single Heater InstallationHorizontal Outside Air Supply for Double Heater Installation Vertical Outside Air Supply for Double Heater InstallationGAS Piping Correct Positions Incorrect Positions Wrong InstallationWiring Line Voltage Thermostat WiringLow Voltage Thermostat with One Burner Page For External Thermostat Connection Internal WiringLadder Diagram Pre-Season Maintenance and Annual Inspection Operation and MaintenanceSequence of Operation To Shut Off HeaterMaintenance Checklist Vicinity of the Heater Installation Code and Annual InspectionsVehicles and Other ObjectsReflector Support Straps Safety LabelsTubes Gas LineTroubleshooting LED Status Indicates Honeywell SmartValve II TroubleshootingTroubleshooting Flow Chart Yes Natural Gas LP Gas Manifold Gas Pressure SettingReplacement Parts Motor and Blower Assembly Blower Inlet Gasket Door Switch Description Part Number Dimensions General SpecificationsGAS Pressure AT Manifold Pipe ConnectionWarranty is Void if ROBERTS-GORDON LLC will not PAY forLimitations on Authority Representatives Page Page Page
Related manuals
Manual 2 pages 4.23 Kb

HE-125, HE-150, HE-100, HE-40, HE-175 specifications

Roberts Gordon is renowned for its innovative heating solutions, and among its standout offerings are the HE-125, HE-175, HE-100, HE-150, and HE-40 heaters. These products exemplify cutting-edge technology and efficiency designed for commercial and industrial applications.

The HE-125 and HE-175 variants are among the top-rated infrared heaters available. They utilize advanced infrared technology to provide direct heating to objects, reducing the need to heat the entire ambient air volume. This method results in energy savings while delivering consistent warmth where it's needed most. The HE-125 model has a heating capacity of 125,000 BTU, while the HE-175 pushes this to 175,000 BTU, making them suitable for larger spaces like warehouses and manufacturing facilities.

The HE-100 and HE-150 heaters are designed for flexibility and efficiency in a range of operational environments. These models support a wide range of input fuels including natural gas and propane, making them an adaptable choice for various setups. The HE-100 has an output of 100,000 BTU, and the HE-150 follows with 150,000 BTU. Both units are engineered with robust construction materials, ensuring durability and longevity, while also featuring advanced safety systems to prevent overheating and other hazards.

In contrast, the HE-40 heater stands out for smaller spaces, making it an ideal option for garages, workshops, or smaller commercial environments. With a capacity of 40,000 BTU, it effectively delivers consistent warmth without the excessive energy consumption associated with larger units.

All Roberts Gordon models prioritize energy efficiency, often meeting or exceeding current energy codes. They incorporate advanced control systems that allow precise temperature regulation, further optimizing energy use. Additionally, the heaters are designed with minimal maintenance needs, featuring durable components that ensure long-term reliability and performance.

With a legacy of quality and innovation, Roberts Gordon continues to set the standard in infrared heating technology. The HE series exemplifies a commitment to efficiency, safety, and versatility, making them suitable for a wide range of commercial and industrial applications. Whether heating a vast warehouse or a small workshop, these heaters provide reliable performance tailored to user needs.