Rinnai RHFE-1510F manual Dip Switch Settings

Page 14

Dip Switch Settings

Central Timer

Stand Alone

Control

Control

off on

off on

1

2

3

4

1Computer Programming

2Computer Programming

3Central Control System

4Emergency Cut Off

If controlled by a central timer, dip switch 3 must be in the ON position.

To use a time clock you will also require a transformer and sub PCB available from Rinnai.

When a time clock is used the appliance On/Off button will not operate.

If Emergency cutoff loses signal unit will stop.

Emergency Cut Off can not be used with

Central Control System.

Fault Codes

 

HI

Overheat

Blocked Flue Terminal

 

 

 

Switch

Blocked Air Filter

 

 

 

 

Power Failure

 

 

 

 

Warm Air Obstruction

 

 

 

 

Gas Type

 

 

 

 

Gas Pressure

 

 

 

 

Convection Fan coil resistance

 

 

 

 

PCB voltage to Convection Fan

 

 

 

 

PCB voltage to Overheat Circuit

 

 

 

 

Thermal Fuse Resistance

 

 

 

 

Overheat Switch Resistance

 

 

CI

Room Temp

Room Temp Thermistor Resistance

 

 

 

Sensor Faulty

 

 

 

C2

Overheat Temp

Overheat Thermistor Resistance

 

 

 

Sensor Faulty

 

 

 

H6

Overheat

Thermal Fuse

 

 

dI

Sparker Failure

PCB

 

 

 

 

Sparker input voltage

 

 

 

 

Spark Gap

 

 

 

No Ignition

Flame Rod carboned up

 

 

bI & Com-

 

PCB

 

 

 

Blocked burner ports

 

 

bustion Lamp

 

 

 

 

Blocked Flue Terminal

 

 

 

 

 

 

 

 

Gas Type

 

 

 

 

Combustion Fan

 

 

 

 

Gas Pressure

 

 

EO

Communication

PCB

 

 

 

Error (Ghost

Flame Sensor

 

 

 

Flame)

Sparker

 

 

b3 + Com-

Flame Failure

Physical Blockages

 

 

bustion Lamp

 

Flame Rod

 

 

n2

Air Proving

Blocked Flue

 

 

 

Device

Faulty PCB

 

 

 

 

Combustion Fan

 

 

 

 

Kinked/disconnected air tube

 

 

 

 

Heat Exchanger Blocked

 

 

 

 

Air Proving Senser

 

 

n1

On/Off Button

Check On/Off switch

 

 

 

sub PCB

 

 

 

Faulty

 

 

 

PCB

 

 

 

 

 

27

28

Image 14
Contents Has Warranty Not Flue Terminal Position Diagram on the right shows minimum Open the gas valve fully When Glow the Lock function is set Ure Always Sleeve Plate 400 Fixing Example of flue tube extension Ing Wiring Diagram Dip Switch Settings Maintenance Troubleshooting the Heater WA7 1ST RHFE-1510F

RHFE-1510F specifications

The Rinnai RHFE-1510F is a state-of-the-art gas heater designed to provide efficient heating solutions for homes and businesses. This model is particularly popular for its compact design and advanced technology that ensure reliable performance while being user-friendly.

One of the main features of the Rinnai RHFE-1510F is its powerful heating capacity. It can produce heat output of up to 1,500 watts, making it suitable for various room sizes. The heater utilizes a fan-assisted heat distribution system, ensuring that warmth is evenly spread throughout the space. This feature is vital for maintaining comfort during colder months and enhances the overall efficiency of the unit.

Incorporating advanced technology, the Rinnai RHFE-1510F operates using gas, ensuring low emissions, which is a significant benefit for environmentally-conscious users. The unit is equipped with a highly efficient combustion system, allowing for optimal gas usage without sacrificing performance. This not only translates to lower energy bills but also reduces the environmental footprint of heating your space.

The design of the Rinnai RHFE-1510F is sleek and modern, allowing it to fit seamlessly into a variety of interiors. Its compact size makes it particularly appealing for homes where space is at a premium. Moreover, the unit can be mounted on the wall, helping to save floor space and providing more flexibility in room layout.

Safety is paramount in the design of the Rinnai RHFE-1510F. It includes an automatic shut-off feature that activates in the event of overheating or if the unit detects any irregularities during operation. Additionally, the device is equipped with a child lock function, ensuring that it is safe for households with young children.

User control is another highlight of the Rinnai RHFE-1510F. It comes with a user-friendly remote control, allowing you to adjust settings from a distance. This feature enhances convenience, allowing users to easily set desired temperatures or switch modes without having to get up.

In summary, the Rinnai RHFE-1510F combines power, energy efficiency, and design into a compact heating solution. Its innovative technology, safety features, and ease of use make it an excellent choice for those seeking reliable heating in their spaces. It stands as a testament to Rinnai's commitment to quality and customer satisfaction in the home heating market.