R & M Int'l CGC-1e warranty PPM Part-Per-Million CO2 Control Mode, PPM-1c

Page 7

PPM (Part-Per-Million) CO2 CONTROL MODE

As mentioned previously, the CGC-1e can control CO2 levels within the growing area with “Part-Per-Million” accuracy when used in conjunction with the PPM-1c controller. Simply removing the jumper plug and connecting the PPM-1c into the standard quick-disconnect on the bottom of the CGC-1e instantly gives you the ability to fully control all atmospheric conditions which affect timed CO2 systems.

*Note: The CO2 Frequency timer acts as a CO2 sample timer when using the PPM-1c controller. Because it may take a couple of minutes from the time CO2 is released for the PPM-1c to detect a higher CO2 level, this timer will provide a delay for the PPM controller to sense this increase in the CO2 level before releasing more CO2. If you find the CO2 level is “overshooting” the CO2 set-point, try increasing the CO2 sample timer or decrease the CO2 Inject timer. This will give the PPM-1c more time to sense the rise in CO2 resulting in reduced “overshoot”.

THE PPM-1c

The PPM-1c controller consists of an infrared detector capable of measuring atmospheric CO2 levels from 0 to 5000 PPM. The PPM-1c is powered by an 18 vdc to 24vac power supply. When it is connected, it will enter a “warm-up” mode. Once the PPM-1c has completed the “warm-up”, it will begin to self calibrate. This may take an additional minute. During this time, the digital readout may be fluctuating, this is normal. When the digital readout stabilizes, a level between 350 to 650 should be displayed. Be careful however, simply breathing on the PPM-1c controller will greatly increase the CO2 level in the air resulting in a higher reading.

IMPORTANT!!! Do not start a CO2 cycle until the PPM-1c has completed the “warm-up” and the display has stabilized.

Once the PPM-1c has been connected, it remains powered as long as it is plugged in. The controller will continuously display the exact CO2 PPM level in part per million.

The PPM-1c is a portable device and comes with a 5-foot cable so that spot checks can be made.

A simple procedure allows the user to check and reset calibration… otherwise; the PPM-1c requires no adjustment or service.

Warning: Be careful not to expose the PPM-1cto water, as it is not water-resistant!

Page 7

Image 7
Contents Overview WarrantyInstallation / START-UP Do not use 2-wire adapters or cords to operate the CGC-1eFront Panel Example Connection Diagram do not Exceed 15 Amps TotalHOW to START-UP the CGC-1e START-UP ProcedureControls CO2 Timers TimersAdjustable Recycling Timers Hydroponics TimersCO2 Control Modes Timed CO2 Control ModeCO2 Control Supplemental CO2PPM-1c PPM Part-Per-Million CO2 Control ModeMaster Lighting Controller MLCs Universal Power Module UPM-1Options PART-PER-MILLION CO2 Sensor PPM-1cMaking Connections TroubleshootingALL Rights Reserved Maintenance / SpecificationsSpecifications Maintenance